Background: Substantial fibular torsional deformities were detected after surgery for ankle fractures combined with a lesion of the syndesmotic complex using a novel CT analyzing method.
Methods: In a prospective study, 61 patients with ankle fracture dislocations were treated with trans-syndesmotic screw fixation of the distal tibiofibular joint. Postoperative axial CT scans of both lower legs under standardized leg positioning conditions were made and analyzed with three different methods. Method 1 (M1) used proximal and distal CT planes of the lower leg for detection of the fibular torsional angle, method 2 (M2) considered only the angle at the distal tibiofibular joint, and method 3 (M3) measured the angles between the fibular and tibial tangents at the distal tibiofibular joint. Twenty patients with fibular torsional asymmetries of more than 10 degrees were evaluated clinically 6 to 34 months postoperatively with the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Score.
Results: Thirty-five of the 61 patients had torsional side-to-side differences of more than 10 degrees. M1 and M2 showed statistically significant differences compared to M3 (p = 0.001). Validity was controlled by interobserver data, variation coefficients were low for M1 and M2. Clinically, six of 20 patients with torsional differences of more than 10 degrees had excellent results, while seven had good results and seven had moderately functional results. Six of the seven with moderate results had fibular torsional differences of more than 15 degrees, two of the seven patients with good outcomes. Torsional results of M1 and M2 correlated with the AOFAS score (r = -0.506).
Conclusions: Of the 61 ankle fractures with ruptures of the syndesmotic complex, 25% showed torsional side-to-side differences of more than 10 degrees on proximal and distal CT planes. This CT technique correlated with the AOFAS score and could help determine when early operative revision is indicated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/107110070602701219 | DOI Listing |
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
December 2024
Department of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Objective: To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test.
Methods: A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint.
Injury
September 2024
Hip Department (CAD) Gaetano Pini-CTO Orthopedic Institute, University of Milan, P.za Cardinal Ferrari 1, 20122, Milano, Italy.
Background And Purpose: Residual axial and rotational deformities in tibial shaft fracture, after minimally invasive osteosynthesis (MIO) treatment, are widely described in literature. Nevertheless, there is still a lack of evidence about the malunion treatment strategies and results. The aim of our study is to present an innovative technique for tibial shaft malunion: a derotational proximal tibial osteotomy without removing the original plate (Plate-Retaining-Osteotomy: PR-Osteotomy).
View Article and Find Full Text PDFFront Bioeng Biotechnol
September 2024
Department of Orthopedic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, China.
Introduction: Low bone density and lack of medial support are the two most important factors affecting the stability of locking plate fixation for osteoporotic proximal humeral fractures (PHFs). This study aimed to compare the biomechanical characteristics of PHILOS locking plates combined with calcar screws, bone cement, fibular allografts, and medial locking plate support strategies for treating osteoporotic PHFs with medial column instability.
Methods: A three-part osteoporotic PHF (AO 11-B3.
J Orthop Trauma
October 2024
Department for Orthopaedics and Rehabilitation, Penn State College of Medicine, Hershey, PA.
Objectives: A variable pitch locking screw is intended to provide interfragmentary compression combined with fixed angle stability of locking plate constructs. The objective of this study was to compare variable pitch locking screws (3.5-mm KreuLock Ti locking compression screws, Arthrex Inc.
View Article and Find Full Text PDFJSES Rev Rep Tech
August 2024
Division of Orthopedic Surgery, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
Fractures of the proximal humerus account for 4%-8% of injuries to the appendicular skeleton. Most are stable, minimally displaced osteoporotic fractures in the elderly, and are the result of low-energy falls. A large majority of these patients regain adequate shoulder function without operative intervention.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!