Conformational changes and aggregation of alginic acid as determined by fluorescence correlation spectroscopy.

Biomacromolecules

Analytical and Biophysical Environmental Chemistry, University of Geneva, 30 Quai E. Ansermet, Geneva CH-1211, Switzerland.

Published: January 2007

Insight into the conformations and aggregation of alginic acid was gained by measuring its diffusion coefficient at very dilute concentrations using fluorescence correlation spectroscopy. Both the pH and ionic strength (I) had an important influence on the diffusion coefficient of the polysaccharide. For pH, three effects were isolated: (i) below pH 4, the charge density decreased causing increased aggregation; (ii) between pH 4 and 8, a molecular expansion was observed with increasing pH, whereas (iii) above pH 8 some dissociation of the polymer was observed. Increasing I from 0.001 to 0.1 M resulted in a ca. 20% increase in the diffusion coefficient. By coupling these measurements to molar mass determinations obtained by size exclusion chromatography and monomer size estimations determined from ab initio calculations, it was possible to determine the radii of gyration via de Gennes renormalization theory. From diffusion coefficients and radii of gyration obtained as a function of ionic strength, persistence lengths (total, electrostatic, and intrinsic) were calculated from the Benoit-Doty relationship.

Download full-text PDF

Source
http://dx.doi.org/10.1021/bm060655dDOI Listing

Publication Analysis

Top Keywords

diffusion coefficient
12
aggregation alginic
8
alginic acid
8
fluorescence correlation
8
correlation spectroscopy
8
ionic strength
8
observed increasing
8
radii gyration
8
conformational changes
4
changes aggregation
4

Similar Publications

The impact of colloid-solvent dynamic coupling on the coarsening rate of colloidal phase separation.

J Colloid Interface Sci

January 2025

Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, 153-8904, Tokyo, Japan; Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, 153-8505, Tokyo, Japan. Electronic address:

Phase separation, a fundamental phenomenon in both natural and industrial settings, involves the coarsening of domains over time t to reduce interfacial energy. While well-understood for simple viscous liquid mixtures, the physical laws governing coarsening dynamics in complex fluids, such as colloidal suspensions, remain unclear. Here, we investigate colloidal phase separation through particle-based simulations with and without hydrodynamic interactions (HIs).

View Article and Find Full Text PDF

Healthy brain aging involves changes in both brain structure and function, including alterations in cellular composition and microstructure across brain regions. Unlike diffusion-weighted MRI (dMRI), diffusion-weighted MR spectroscopy (dMRS) can assess cell-type specific microstructural changes, providing indirect information on both cell composition and microstructure through the quantification and interpretation of metabolites' diffusion properties. This work investigates age-related changes in the higher-order diffusion properties of total N-Acetyl-aspartate (neuronal biomarker), total choline (glial biomarker), and total creatine (both neuronal and glial biomarker) beyond the classical apparent diffusion coefficient in cerebral and cerebellar gray matter of healthy human brain.

View Article and Find Full Text PDF

There is limited knowledge on diffusing capacity in scoliosis patients. It remains to be determined if impaired pulmonary diffusing capacity is mostly influenced by reduced alveolar-capillary membrane diffusing capacity (D), reduced pulmonary capillary blood volume (V) or both. This study aims to report findings from dual test gas pulmonary diffusing capacity for carbon monoxide and nitric oxide (D) with quantification of pulmonary diffusing capacity for carbon monoxide corrected for haemoglobin with a five s breath-hold (D) and nitric oxide with a five s breath-hold (D), D and V.

View Article and Find Full Text PDF

In this study, we employed a novel fluorescent probe, RO7304924-which selectively targets cannabinoid 2 receptor (CB2R)-to assess the lateral mobility of CB2R within the plasma membrane of Chinese hamster ovary cells stably expressing a functional, untagged receptor variant. Utilizing confocal fluorescence recovery after photobleaching (FRAP), we quantified the diffusion coefficient and mobile fraction of CB2R, thereby demonstrating the efficacy of RO7304924 as an innovative tool for elucidating the dynamics of this major endocannabinoid-binding G protein-coupled receptor. Our present findings highlight the potential of combining advanced ligand-based fluorescent probes with FRAP for future investigations into the biochemical details of CB2R mobility in living cells, and its impact on receptor-dependent cellular processes.

View Article and Find Full Text PDF

We present the first, to our knowledge, metasurface holographic display method with exceptional fidelity and minimal edge noise, based on highly uniform flat-top light generated by a digital micromirror device (DMD). Based on the error-diffusion algorithm and iterative refinement process, the amplitude distribution of the initial Gaussian light was dynamically closed-loop modulated, and the standard difference of the intensity of the 3 mm diameter center flat-top beam was reduced to less than 3.4%.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!