A rapid, inexpensive and reliable procedure for separation and purification of C-phycocyanin (C-PC) and allophycocyanin (APC) from Arthronema africanum based on a previously described rivanol-sulfate method for C-PC purification was developed. Exclusion of NaCl from the extraction buffer resulted in complete separation of APC and C-PC, two-fold reduction of rivanol treatments, and a higher yield and purity of C-PC. Pure C-PC (A(620)/A(280) of 4.52) and APC (A(652)/A(280) of 2.41) were obtained. The estimated molecular masses of the alpha and beta subunits were 17 and 19 kDsmall a, Cyrillic for capital ES, Cyrillic-phycocyanin and 16 and 18 kDsmall a, Cyrillic for APC, respectively. The overall C-PC recovery of 55% (w/w) from its content (100 mg) in the crude extract was 10-20% higher than so far reported. The procedure appears promising for scaling up and broader applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10529-006-9274-5 | DOI Listing |
Sleep Breath
January 2025
Department of Pulmonary and Critical Care Medicine, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Da Hua Road, Dong Dan, Dongcheng District, Beijing, 100730, PR China.
Purpose: To investigate the relationship between obstructive sleep apnea hypopnea syndrome (OSAHS) severity and fat, bone, and muscle indices.
Methods: This study included 102 patients with OSAHS and retrospectively reviewed their physical examination data. All patients underwent polysomnography, body composition analysis, dual-energy X-ray absorptiometry, computed tomography (CT) and blood test.
Ophthalmic Physiol Opt
January 2025
Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.
Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.
View Article and Find Full Text PDFRadiat Oncol
January 2025
Department of Radiation Oncology, Key Laboratory of Cancer Prevention and Therapy, Tianjin Medical University Cancer Institute & Hospital, National Clinical Research Center for Cancer, Tianjin's Clinical Research Center for Cancer, Tianjin, 300060, China.
Background: Several studies have suggested that lung tissue heterogeneity is associated with overall survival (OS) in lung cancer. However, the quantitative relationship between the two remains unknown. The purpose of this study is to investigate the prognostic value of whole lung-based and tumor-based radiomics for OS in LA-NSCLC treated with definitive radiotherapy.
View Article and Find Full Text PDFBiomed Eng Online
January 2025
Department of Medical Ultrasound, Maoming People's Hospital, Maoming, Guangdong, 525011, People's Republic of China.
Background: Epidermal growth factor receptor (EGFR) gene mutations can lead to distant metastasis in non-small cell lung cancer (NSCLC). When the primary NSCLC lesions are removed or cannot be sampled, the EGFR status of the metastatic lesions are the potential alternative method to reflect EGFR mutations in the primary NSCLC lesions. This review aimed to evaluate the potential of magnetic resonance imaging (MRI) radiomics based on extrapulmonary metastases in predicting EGFR mutations through a systematic reviews and meta-analysis.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Optometry, School of Rehabilitation, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Background: The psychometric properties of the Convergence Insufficiency Symptom Survey (CISS) have been previously determined across the younger adult population. This study investigated the psychometric properties of the CISS in presbyopic adults via classical and Rasch analysis.
Methods: A total of 100 presbyopic individuals (40-60 years) were selected with far and near acuity of 20/20 with their habitual spectacles; 50 had convergence insufficiency and 50 had normal binocular vision.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!