Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.

Phys Med Biol

Department of Radiation Oncology, The University of Virginia, Charlottesville, VA, and Department of Radiology, Children's Hospital of Philadelphia, PA, USA.

Published: January 2007

Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproducibility on the imaging acquisition parameters, specifically the scan time and the frame rate. Three healthy subjects underwent a continuous 5 min magnetic resonance (MR) scan in the sagittal plane with a frame rate of approximately 10 f s-1, and the experiments were repeated with an interval of 2 to 3 weeks. A total of nine pulmonary vessels from different lung regions (upper, middle and lower) were tracked and the dependences of their displacement PDF reproducibility were evaluated as a function of scan time and frame rate. As results, the PDF reproducibility error decreased with prolonged scans and appeared to approach equilibrium state in subjects 2 and 3 within the 5 min scan. The PDF accuracy increased in the power function with the increase of frame rate; however, the PDF reproducibility showed less sensitivity to frame rate presumably due to the randomness of breathing which dominates the effects. As the key component of the PDF-based treatment planning, the reproducibility of the PDF affects the dosimetric accuracy substantially. This study provides a reference for acquiring MR-based PDF of structures in the lung.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/52/2/004DOI Listing

Publication Analysis

Top Keywords

frame rate
20
pdf reproducibility
16
pdf
10
probability distribution
8
distribution function
8
function pdf
8
treatment planning
8
reproducibility pdf
8
scan time
8
time frame
8

Similar Publications

An Improved Method for Extracting Rat Cerebrospinal Fluid with Repeatable Large-Scale Collection.

Vet Sci

January 2025

Guangzhou Bay Area Institute of Biomedicine, Guangdong Lewwin Pharmaceutical Research Institute Co., Ltd., Guangdong Provincial Key Laboratory of Drug Non-Clinical Evaluation and Research, TCM Non-Clinic Evaluation Branch of National Engineering Research Center for Modernization of Traditional Chinese Medicine, Guangdong Engineering Research Center for Innovative Drug Evaluation and Research, Guangzhou 510990, China.

The aim of this study was to explore an improved method for extracting rat cerebrospinal fluid (CSF), observing the impact on animal health under conditions of large-scale CSF collection and evaluating the feasibility of repeated collections. A total of 20 rats were anesthetized and fixed in a stereotactic frame. A 26G scalp needle, combined with a 1 mL syringe, was used to puncture the atlanto-occipital membrane and collect approximately 170 μL of CSF.

View Article and Find Full Text PDF

Intraoperative Augmented Reality for Vitreoretinal Surgery Using Edge Computing.

J Pers Med

January 2025

Department of Ophthalmology, Mayo Clinic, Rochester, MN 55905, USA.

: Augmented reality (AR) may allow vitreoretinal surgeons to leverage microscope-integrated digital imaging systems to analyze and highlight key retinal anatomic features in real time, possibly improving safety and precision during surgery. By employing convolutional neural networks (CNNs) for retina vessel segmentation, a retinal coordinate system can be created that allows pre-operative images of capillary non-perfusion or retinal breaks to be digitally aligned and overlayed upon the surgical field in real time. Such technology may be useful in assuring thorough laser treatment of capillary non-perfusion or in using pre-operative optical coherence tomography (OCT) to guide macular surgery when microscope-integrated OCT (MIOCT) is not available.

View Article and Find Full Text PDF

Titin truncating variants (TTNtv) are the main genetic cause of dilated cardiomyopathies (DCMs). The phenotype and prognosis of probands have been evaluated in several large cohorts. However, few data are available on intrafamilial expressivity.

View Article and Find Full Text PDF

Frame-based Stereotactic Brain Biopsy (FSBB) is a minimally invasive procedure with a view to increasing the diagnostic yield. The aim of this study was to investigate the accuracy and safety of FSBB with the help of the intraoperative 3D O-ARM system. A preoperative MRI allowed for targeting the tissue to be sampled.

View Article and Find Full Text PDF

Introduction: Endoplasmic reticulum aminopeptidases 1 (ERAP1) and 2 (ERAP2) modulate a plethora of physiological processes for the maintenance of homeostasis in different cellular subsets at both intra and extracellular level.

Materials And Methods: In this frame, the extracellular supplementation of recombinant human (rh) ERAP1 and ERAP2 (300 ng/ml) was used to mimic the effect of stressor-induced secretion of ERAPs on neutrophils isolated from 5 healthy subjects. In these cells following 3 h or 24 h rhERAP stimulation by Western Blot, RT-qPCR, Elisa, Confocal microscopy, transwell migration assay, Oxygraphy and Flow Cytometry we assessed: i) rhERAP internalization; ii) activation; iii) migration; iv) oxygen consumption rate; v) reactive oxygen species (ROS) accumulation; granule release; vi) phagocytosis; and vii) autophagy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!