Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The CobraPLA (CPLA) is a relatively new supraglottic airway device that has not been sufficiently investigated. Here, we performed a prospective observational study to evaluate the efficacy of the CPLA during controlled ventilation. In 50 anesthetized and paralyzed patients undergoing elective surgery a CPLA was inserted and inflated to an intracuff pressure of 60 cm H2O. The success rate of insertion upon the first attempt was 82% (41/50), with a mean insertion time of 16.3 +/- 4.5 seconds. The adequacy of ventilation was assessed by observing the end tidal CO2 waveform, movement of the chest wall, peak airway pressure (13.5 cm H2O), and leak fraction (4%). We documented the airway sealing pressure (22.5 cm H2O) and noted that the the site of gas leaks at that pressure were either at the neck (52%), the abdomen (46%), or both (2%). In 44 (88%) patients, the vocal cords were visible in the fiberoptic view through the CPLA. There was no gastric insufflation during the anesthesia. Respiratory and hemodynamic parameters remained stable during CPLA insertion. Postoperative blood staining of CPLA was minimal, occurring in 22% (11/50) of patients. Mild and moderate throat soreness was reported in 44% (22/50) and 4% (2/50) of patients, respectively. Lastly, mild dysphonia was observed in 6% (3/50) of patients and mild dysphagia in 10% (5/50) of patients. Our results indicated that the CPLA is both easy to place and allows adequate ventilation during controlled ventilation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2687819 | PMC |
http://dx.doi.org/10.3349/ymj.2006.47.6.799 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!