Previous studies have applied balanced steady-state free precession (bSSFP) to functional brain imaging. Methods that exploit the strong frequency dependence of the MR signal in the bSSFP transition band are strongly affected by field inhomogeneity and frequency drifts. Recent bSSFP studies using "on-resonance" (in the bSSFP passband) acquisition claimed that higher sensitivity was achieved compared to traditional fMRI methods. However, the contrast mechanism that generates activation-related signal changes in bSSFP imaging is not yet fully understood. We performed a systematic study of on-resonance bSSFP signal behavior using a multiecho balanced SSFP sequence with different TRs at 3 Tesla. We conclude that intravoxel dephasing, or the off-resonance averaged steady state, dominates the bSSFP signal decay and determines the bSSFP fMRI contrast. Experimental findings were confirmed by simulations based on existing theories for signal formation around blood vessels in inhomogeneous tissues. The activation-induced signal change in on-resonance bSSFP increases with TE, and the TE dependence of the contrast-to-noise ratio (CNR) in bSSFP is similar to that in gradient echo-planar imaging (GE-EPI). However, GE-EPI has a significantly higher CNR efficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.21103DOI Listing

Publication Analysis

Top Keywords

bssfp
10
balanced steady-state
8
steady-state free
8
free precession
8
on-resonance bssfp
8
bssfp signal
8
signal
6
systematic investigation
4
investigation balanced
4
precession functional
4

Similar Publications

Parametric mapping has become a standard of care technique for the non-invasive assessment of myocardial edema and fibrosis. Conventional MOLLI-based T1 mapping is susceptible to many confounding effects particularly in the pediatric population. The requirement for compliant breath holds is a major limitation for younger or more ill patients.

View Article and Find Full Text PDF

Purpose: To investigate image quality and agreement of derived cardiac function parameters in a novel joint image reconstruction and segmentation approach based on disentangled representation learning, enabling real-time cardiac cine imaging during free-breathing.

Methods: A multi-tasking neural network architecture, incorporating disentangled representation learning, was trained using simulated examinations based on data from a public repository along with MR scans specifically acquired for model development. An exploratory feasibility study evaluated the method on undersampled real-time acquisitions using an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation.

View Article and Find Full Text PDF

Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI.

J Magn Reson Imaging

January 2025

Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.

Background: At high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI.

Purpose: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI.

Study Type: Prospective.

View Article and Find Full Text PDF

Purpose: This study proposes a novel, contrast-free Magnetic Resonance Fingerprinting (MRF) method using balanced Steady-State Free Precession (bSSFP) sequences for the quantification of cerebral blood volume (CBV), vessel radius (R), and relaxometry parameters (T , T , T *) in the brain.

Methods: The technique leverages the sensitivity of bSSFP sequences to intra-voxel frequency distributions in both transient and steady-state regimes. A dictionary-matching process is employed, using simulations of realistic mouse microvascular networks to generate the MRF dictionary.

View Article and Find Full Text PDF

Ultra-high-resolution brain MRI at 0.55T: bSTAR and its application to magnetization transfer ratio imaging.

Z Med Phys

January 2025

Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland; Department of Radiology, Division of Radiological Physics, University Hospital Basel, Basel, Switzerland.

Purpose: This study aims to evaluate the feasibility of structural sub-millimeter isotropic brain MRI at 0.55 T using a 3D half-radial dual-echo balanced steady-state free precession sequence, termed bSTAR and to assess its potential for high-resolution magnetization transfer imaging.

Methods: Phantom and in-vivo imaging of three healthy volunteers was performed on a low-field 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!