Aim: To measure the rise in temperature during mechanical removal of residual adhesive after debonding of brackets in vitro.

Methods: Different carbide burs on a high-speed handpiece were tested. Acrylic on the buccal surfaces of recently extracted human maxillary incisors was removed using 3 types of carbide burs (6-, 12-, 40-fluted) with a varying number of windings relative to the long axis of the shaft. The temperature was measured using a thermocouple probe in the pulp chamber of the extracted teeth.

Results: The highest mean rise in temperature was measured using a 6-fluted bur (+9.4 degrees C, P < .001), followed by the 12-fluted bur (+6.5 degrees C, P <.001). The lowest rise in temperature (+1.2 degrees C, not significant) was seen with a 40-fluted bur. After 3 to 8 seconds of continuous grinding, the rise in temperature seems to slow down.

Conclusion: The removal of residual adhesive after debonding is best performed with fine burs. If 6-fluted burs are used, a pause after 5 to 10 seconds of continuous grinding is recommended, especially in the mandibular anterior area.

Download full-text PDF

Source

Publication Analysis

Top Keywords

residual adhesive
8
debonding brackets
8
rise temperature
8
carbide burs
8
temperature measured
8
heat generated
4
generated residual
4
adhesive removal
4
removal debonding
4
brackets aim
4

Similar Publications

Objective: This study evaluated dentin morphology and pulp cavity temperature changes during nanosecond‑ and microsecond‑pulse Er, Cr: YSGG laser debonding restoration and residual adhesive.

Materials And Methods: Ten caries-free teeth had their enamel removed perpendicular to the long axis, followed by bonding of glass ceramic restorations. The samples were randomly divided into two groups and subjected to Er, Cr: YSGG laser (3 mJ, 100 Hz, 100 ns), (3 mJ, 100 Hz, 150 µs) for debonding of restoration and residual adhesive on dentin surfaces.

View Article and Find Full Text PDF

In-Situ Cross-Linked Polymers for Enhanced Thermal Cycling Stability in Flexible Perovskite Solar Cells.

Angew Chem Int Ed Engl

December 2024

Key Lab for Special Functional Materials of Ministry of Education, National & Local Joint Engineering Research Center for High-efficiency Display and Lighting Technology, School of Nanoscience and Materials Engineering, Collaborative Innovation Center of Nano Functional Materials and Applications, Henan University, Kaifeng, 475004, P. R. China.

Flexible perovskite solar cells (FPSCs) are a promising emerging photovoltaic technology, with certified power conversion efficiencies reaching 24.9 %. However, the frequent occurrence of grain fractures and interface delamination raises concerns about their ability to endure the mechanical stresses caused by temperature fluctuations.

View Article and Find Full Text PDF

The combination of hip arthroscopy and periacetabular osteotomy (PAO) has been proven safe and effective for addressing symptoms in patients with developmental dysplasia of the hip (DDH). As not every patient with dysplasia will require a hip arthroscopy to obtain desired clinical improvement in the setting of periacetabular osteotomy, a challenge is identifying which patients require adjacent procedures (either via arthroscopic or open) to fully treat their hip pathology. Even though labral repair is the most reported arthroscopic procedure in cases of hip dysplasia, I would suggest that labral treatment is the least likely helpful component of hip arthroscopy in these cases.

View Article and Find Full Text PDF

This study examines the enhancement of the mechanical strength of polymer resins through reinforcement with synthetic (glass) and natural (hemp, jute) fibers, using the TRIZ-ARIZ methodology to optimize composite design for improved mechanical properties, sustainability, and economic efficiency. Mechanical testing, thermogravimetric analysis (TGA), and scanning electron microscopy (SEM) were conducted to evaluate the properties of the composite materials. Regarding tensile strength testing, the results showed the following: jute fiber achieved the best results, with a maximum tensile values of 43.

View Article and Find Full Text PDF

Postoperative adhesion around nerves sometimes results in sensory and motor dysfunctions. To prevent these disorders, we have developed an electrospun nanofiber sheet incorporating methylcobalamin (MeCbl), an active form of vitamin B12 with anti-inflammatory and neuroregenerative effects. This study aimed to investigate the neuroprotective effects of MeCbl sheets against postoperative adhesion and to compare the effects of MeCbl sheets with those of porcine small intestinal submucosa (SIS) sheets using a rat sciatic nerve adhesion model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!