A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Thermal injury caused by chandelier fiber probe. | LitMetric

Thermal injury caused by chandelier fiber probe.

Am J Ophthalmol

Department of Ophthalmology, School of Medicine, Surugadai Hospital of Nihon University, 1-8-13 Surugadai, Kanda, Chiyodaku, Tokyo 101-8309, Japan.

Published: January 2007

Purpose: To investigate thermal changes produced by a chandelier fiber probe (CFP).

Design: Interventional single case report and laboratory investigation.

Methods: When CFP was used for 25-gauge vitrectomy, an abnormal odor was emitted, and the CFP was instantly removed. To investigate this incident, the thermal change produced by the CFP was measured in air by means of an infrared sensor. Porcine Tenon capsular tissue was used to reproduce the intraoperative phenomenon.

Results: In our patient, the CFP tip melted, but this did not affect visual function. In the experiment, the uncoated CFP reached 49 C (120 F) at maximum illumination. When porcine Tenon capsular tissue was attached to the CFP tip, a temperature of 144 C (291 F) was reached at 50% of maximum illumination, and over 201 C (394 F) at 75%. The tip melted under these conditions.

Conclusions: At present, we avoid the use of CFP during air exchange. This potential hazard of the CFP needs to be addressed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajo.2006.07.049DOI Listing

Publication Analysis

Top Keywords

chandelier fiber
8
fiber probe
8
cfp
8
porcine tenon
8
tenon capsular
8
capsular tissue
8
maximum illumination
8
thermal injury
4
injury caused
4
caused chandelier
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!