A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Effect of dialysis time in vivo on recovery of amino acids for micro-dialysis probe]. | LitMetric

[Effect of dialysis time in vivo on recovery of amino acids for micro-dialysis probe].

Zhejiang Da Xue Xue Bao Yi Xue Ban

Key Laboratory of Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China.

Published: November 2006

Objective: To investigate the variety of vitro recovery of amino acids for microdialysis probe after different dialysis time in vivo.

Methods: Probes were dialyzed in the amino acids standard solutions with microdialysis system,amino acid standard solutions and the microdialysate of probe were detected by the method of precolumn derivation with HPLC-RF.

Result: After using different time of probe made by regenerated cellulose membrane, the vitro recoveries of Asp, Glu and GABA were not completely same (Asp: F=19.669, P=0.000; Glu: F=103.955, P=0.000; GABA: F=3.454, P=0.040); while the vitro recovery of Tau had no obvious difference(F=2.001, P=0.152). After using 6 h in vivo, recovery remain percentage (RRP) of Asp, Glu,Tau and GABA was 64.34 %, 67.36%, 103.11 % and 98.23 %, respectively, the recoveries of Asp, Glu decreased obviously (Asp: P < 0.01,Glu: P <0.05). After using 12 h in vivo, the RRP of Asp, Glu, Tau and GABA was 43.44 %, 24.42%, 77.45 % and 67.36 %, respectively, the recoveries of Asp, Glu and GABA decreased obviously (Asp: P < 0.001, Glu: P < 0.001, GABA: P < 0.05). After using 24 h in vivo, the RRP of Asp, Glu,Tau and GABA was 36.26 %, 12.24 %, 89.48 % and 71.35 %, respectively, the recoveries of Asp, Glu, GABA decreased obviously (Asp: P < 0.0001, Glu: P < 0.0001, GABA: P < 0.01).

Conclusion: Dialysis in vivo could lead to the decline of recovery of probe, the decline is more obvious after longer dialysis. So when making brain dialysis experiments, the use time of probe should not be too long. To improve the validity of data, some calibration should be made on the recoveries of probe.

Download full-text PDF

Source
http://dx.doi.org/10.3785/j.issn.1008-9292.2006.06.012DOI Listing

Publication Analysis

Top Keywords

amino acids
12
dialysis time
8
vivo recovery
8
recovery amino
8
vitro recovery
8
standard solutions
8
recoveries asp
8
asp glu
8
asp
5
[effect dialysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!