Facilitated stent delivery using applied topical lubrication.

Catheter Cardiovasc Interv

Division of Cardiology, Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, PA 19107, USA.

Published: February 2007

Objectives: The goal of this study was to assess the utility of topical lubrication to aid stent delivery in challenging anatomy and its effects on long-term clinical outcome.

Background: Failed stent delivery is encountered in up to 5% of percutaneous coronary interventions (PCI).

Methods: The effectiveness of topically applied lubrication to facilitate stent delivery after failed stent placement was evaluated in 20 (2.5%) out of 813 consecutive patients undergoing PCI. Initial attempts at stent delivery failed despite balloon predilatation and use of moderate-to-stiff guidewires in all patients. The lubricious solution used was Rotaglide, a phospholipid emulsion originally designed to reduce catheter friction during rotational atherectomy. Following unsuccessful delivery, stents were removed from the guiding catheters, topically saturated with Rotaglide, and deployment immediately reattempted. Procedural efficacy and long-term clinical outcomes were assessed.

Results: The study population included 20 patients aged 69 +/- 10 years, all of whom had complex lesions (ACC/AHA Class B(2) or C). Rotaglide lubricated stents were successfully deployed at the target lesions in 17 of the 20 patients (85%). Patients were followed 19.5 +/- 3.2 months after their index procedure. There were no periprocedural complications or subacute stent thromboses. Of the 14 patients with drug-eluting stents, none had clinical restenosis or target vessel revascularization. Target lesion revascularization secondary to restenosis was required in 1 of 3 patients treated with bare-metal stents.

Conclusions: Topical lubrication is a simple and effective aid for stent delivery in complex lesions. Rotaglide appears safe and biocompatible with drug-eluting stents.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.20943DOI Listing

Publication Analysis

Top Keywords

stent delivery
24
topical lubrication
12
aid stent
8
long-term clinical
8
failed stent
8
delivery failed
8
complex lesions
8
drug-eluting stents
8
delivery
7
stent
7

Similar Publications

Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.

Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.

View Article and Find Full Text PDF

Coronary artery calcification is an impediment to percutaneous coronary interventions by obstructing the device pathway or stent deployment. To facilitate percutaneous coronary intervention in such complex lesions, high-pressure balloon dilations, atherectomy procedures, and specialty balloons are used but they all come with considerable limitations and periprocedural complications like dissection and perforation. To surpass these disadvantages, intravascular lithotripsy was introduced which acts by delivering high-pressure pulsatile sonic waves circumferentially thereby destroying the calcium deposits.

View Article and Find Full Text PDF

Trend, clinical characteristics, and pregnancy outcomes of pregnancy associated venous thromboembolism: a retrospective analysis of nearly 10 years.

J Matern Fetal Neonatal Med

December 2025

Department of Vascular Surgery & Interventional Therapy, Fujian Maternity and Child Health Hospital, College of Clinical Medicine for Obstetrics & Gynecology and Pediatrics, Fujian Medical University, Fuzhou, China.

Background: Pregnancy-associated venous thromboembolism (PA-VTE) seriously threatens maternal health. We aimed to investigate the clinical characteristics, risk factors, treatments, and pregnancy outcomes to better prevent and treat PA-VTE.

Methods: PA-VTE patients were selected from 171,898 women who were registered in the Department of Obstetrics of Fujian Maternity and Child Health Hospital from January 2014 to August 2023 and delivered to calculate the incidence.

View Article and Find Full Text PDF

3D printing in palliative medicine: systematic review.

BMJ Support Palliat Care

December 2024

Health Research Institute, School of Design, and Confirm Smart Manufacturing Centre, University of Limerick, Limerick, Ireland

Background: Three-dimensional printing (3DP) enables the production of highly customised, cost-efficient devices in a relatively short time, which can be particularly valuable to clinicians treating patients with palliative care intent who are in need of timely and effective solutions in the management of their patients' specific needs, including the relief of distressing symptoms.

Method: Four online databases were searched for articles published by December 2020 that described studies using 3DP in palliative care. The fields of application, and the relevant clinical and technological data were extracted and analysed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!