Purpose: Intravaginal or extravaginal spermatic cord torsion is a diagnostic challenge for the surgeon and radiologist. Color Doppler sonography can be inaccurate, leading to dangerous false-negative results. To date, no single reliable test has been able to provide 100% diagnostic accuracy. The direct visualization of the twisted cord during emergency high resolution ultrasonography has been proposed to avoid systematic and abusive surgical exploration. The aim of this multicenter study was to assess the validity and reproducibility of high resolution ultrasonography based management of acute scrotum in children.

Materials And Methods: A total of 919 patients from 11 European university hospitals underwent color Doppler sonography and high resolution ultrasonography for acute scrotum between 1992 and 2005. The spermatic cord was studied along its complete length to detect a spiral twist. The surgical findings were correlated with the preoperative results.

Results: A total of 208 patients had spermatic cord torsion proved at surgery. Intratesticular vascularization was absent in the affected testis in only 158 cases (76%). In contrast, high resolution ultrasonography detected the twist as a snail shell-shaped mass, measuring 7 to 33 mm, in 199 patients (96%). High resolution ultrasonography revealed a linear cord for all other causes of acute scrotum (711 patients) with a specificity of 99%. The radiologist training level was the best predictive factor of high resolution ultrasonography reliability (p <0.05).

Conclusions: High resolution ultrasonography based management of acute scrotum is reliable and reproducible. Thanks to its high sensitivity and specificity for the diagnosis of spermatic cord torsion, high resolution ultrasonography can significantly improve the management of acute scrotum in children.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.juro.2006.08.128DOI Listing

Publication Analysis

Top Keywords

high resolution
24
resolution ultrasonography
24
spermatic cord
16
acute scrotum
16
cord torsion
8
color doppler
8
doppler sonography
8
cord
6
high
6
resolution
6

Similar Publications

Fluorescent biosensors offer a powerful tool for tracking and quantifying protein activity in living systems with high temporospatial resolution. However, the expression of genetically encoded fluorescent proteins can interfere with endogenous signaling pathways, potentially leading to developmental and physiological abnormalities. The EKAREV-NLS mouse model, which carries a FRET-based biosensor for monitoring extracellular signal-regulated kinase (ERK) activity, has been widely utilized both in vivo and in vitro across various cell types and organs.

View Article and Find Full Text PDF

Machine learning-based assessment of morphometric abnormalities distinguishes bipolar disorder and major depressive disorder.

Neuroradiology

January 2025

Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China.

Introduction: Bipolar disorder (BD) and major depressive disorder (MDD) have overlapping clinical presentations which may make it difficult for clinicians to distinguish them potentially resulting in misdiagnosis. This study combined structural MRI and machine learning techniques to determine whether regional morphological differences could distinguish patients with BD and MDD.

Methods: A total of 123 participants, including BD (n = 31), MDD (n = 48), and healthy controls (HC, n = 44), underwent high-resolution 3D T1-weighted imaging.

View Article and Find Full Text PDF

Alzheimer's disease (AD) is characterized by the accumulation of amyloid-beta (Aβ) plaques in the brain, contributing to neurodegeneration. This study investigates lipid alterations within these plaques using a novel, label-free, multimodal approach. Combining infrared (IR) imaging, machine learning, laser microdissection (LMD), and flow injection analysis mass spectrometry (FIA-MS), we provide the first comprehensive lipidomic analysis of chemically unaltered Aβ plaques in post-mortem human AD brain tissue.

View Article and Find Full Text PDF

Proton magnetic resonance spectroscopy (MRS) offers a non-invasive, repeatable, and reproducible method for in vivo metabolite profiling of the brain and other tissues. However, metabolite fingerprinting by MRS requires high signal-to-noise ratios for accurate metabolite quantification, which has traditionally been limited to large volumes of interest, compromising spatial fidelity. In this study, we introduce a new optimized pipeline that combines LASER MRS acquisition at 11.

View Article and Find Full Text PDF

All-solid-state lithium metal batteries are regarded as next-generation devices for energy storage due to their safety and high energy density. The issues of lithium dendrites and poor mechanical compatibility with electrodes present the need for developing solid-state electrolytes with high stiffness and damping, but it is a contradictory relationship. Here, inspired by the superstructure of tooth enamel, we develop a composite solid-state electrolyte composed of amorphous ceramic nanotube arrays intertwined with solid polymer electrolytes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!