A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Extended interval for retrieval of vena cava filters is safe and may maximize protection against pulmonary embolism. | LitMetric

Extended interval for retrieval of vena cava filters is safe and may maximize protection against pulmonary embolism.

Am J Surg

The F.H. Sammy Ross, Jr Trauma Center and The Carolinas Laparoscopic and Advanced Surgery Program, Department of Surgery, Carolinas Medical Center, Charlotte, NC, USA.

Published: December 2006

Background: Retrieval of optional vena cava filters (VCF) has been demonstrated to be safe and feasible in injured patients in 4 recent studies. However, 2 pulmonary emboli PE were reported in these studies with mean implant durations less than 19 days. In light of these occurrences, we changed our practice for VCF retrieval when patients had recovered from their injuries and at least 30 days after their discharge, or had been stable on therapeutic anticoagulation for deep venous thrombosis (DVT) or PE for at least 2 weeks. The aim of the current study was to assess the safety of this approach.

Methods: A review of prospectively collected data on optional VCF over a 16-month period. The filters were inserted prophylactically per an institutional practice guideline or for the presence of DVT or PE with a contraindication and/or complication to anticoagulation. All patients underwent duplex imaging of the lower extremities and had pre- and post- retrieval cavagrams. Demographics, duration of implantation, and complications were recorded.

Results: Eighty-three patients had optional VCF inserted since the change in our clinical practice. Indications included prophylaxis for high-risk trauma patients (n = 58), DVT or PE with acute contraindication to therapeutic anticoagulation (n = 22), or complications of anticoagulation (n = 3). Two patients developed lower extremity DVT after filter insertion and 1 patient developed a vena cava thrombosis. Retrieval was successful in 47 of 54 cases (87%) attempted. Median implantation duration was 142 days (range 17-475). A filter strut fracture occurred during retrieval without further consequences. No post-insertion or post-retrieval PE occurred in this study.

Conclusion: Extended intervals for retrieval of VCF are safe and may maximize protection against pulmonary embolism.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjsurg.2006.08.046DOI Listing

Publication Analysis

Top Keywords

vena cava
12
cava filters
8
safe maximize
8
maximize protection
8
protection pulmonary
8
pulmonary embolism
8
therapeutic anticoagulation
8
optional vcf
8
anticoagulation patients
8
retrieval
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!