Purpose: To evaluate tests performed to confirm the position of the Veress needle inserted into the left hypochondrium for creation of pneumoperitonium.
Methods: One hundred patients were submitted to laparoscopic procedure with left hypochondrium puncturing. Needle positioning tests were evaluated. The aspiration test was considered positive when organic material was aspirated; the injection test was considered positive when no increased resistance to liquid injection was observed; the recovery test was considered positive when the liquid injected was not recovered; the saline drop test was considered positive when drops of saline in the syringe disappeared quickly; the initial intraperitoneal pressure test was considered positive when pressure levels were 8 pounds mmHg. A positive aspiration test indicated iatrogenic injury, whereas a positive result in any of the other tests indicated that the tip of the needle was correctly positioned in the peritoneal cavity. Sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) of the tests were calculated by correlating results considered true positives (a), false positives (b), false negatives (c) and true negatives (d), according to the formulas: SE = [a/(a + c)] x 100; SP = [d/(b + d)] x 100; PPV = [a/(a + b)] x 100; NPV = [d(c + d)] x 100.
Results: With regard to the aspiration test, SE and PPV were not applicable, SP was 100% and NPV was 100%. With regard to the injection test, SE was 0%, SP was 100%, PPV was inexistent and NPV was 90%. Both recovery and saline drop tests yielded the following results: SE was 50%, SP was 100%, PPV was 100% and NPV was 94.7%. The initial intraperitoneal pressure test yielded the following results: SE, SP, PPV and NPV were 100%.
Conclusions: When inserting the Veress needle into the left hypochondrium, a negative aspiration test guarantees the absence of iatrogenic injury; the injection test is not reliable to determine incorrect needle positioning, but it accurately detects correct needle positioning; recovery and saline drop tests are not reliable to determine correct needle positioning, but they accurately detect incorrect needle positioning; the initial intraperitoneal pressure test is reliable to determine both correct and incorrect needle positioning, and proved to be the most reliable of the tests analyzed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0102-86502006000600006 | DOI Listing |
PLoS One
January 2025
Instituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Ciudad de México, México.
In laparoscopy, the absence of ergonomics in the instruments affects the performance and efficiency of the surgeon, increasing the likelihood of developing musculoskeletal injuries. This article presents the development of a laparoscopic needle holder with an ergonomic handle and the experience in its use with surgeons in the intracorporeal suturing task. The handle of the laparoscopic needle holder consists of a semi-spherical piece that easily adapts to the palm of the surgeon's hand and improves the posture and ergonomics of the wrist, allowing the direct transmission of rotational movements around the longitudinal axis of the instrument towards the tip.
View Article and Find Full Text PDFJ Imaging
January 2025
Clinic of Medicine, Nord-Trøndelag Hospital Trust, Levanger Hospital, 7601 Levanger, Norway.
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a cornerstone in minimally invasive thoracic lymph node sampling. In lung cancer staging, precise assessment of lymph node position is crucial for clinical decision-making. This study aimed to demonstrate a new deep learning method to classify thoracic lymph nodes based on their anatomical location using EBUS images.
View Article and Find Full Text PDFCurr Oncol
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Leipzig, 04103 Leipzig, Germany.
Background: The aim of this study was to compare microwave ablation (MWA) with and without prior placement of an intra-arterial catheter for the purpose of application of contrast medium (CM).
Methods: 148 patients (45 female, 65.1 ± 14.
Ann Card Anaesth
January 2025
Department of Anaesthesiology, Lilavati Hospital and Research Centre, Mumbai, Maharashtra, India.
We report a case of a 74-year-old female with a retrosternal goiter undergoing video-assisted thoracic surgery (VATS) for a left lung lower lobectomy, necessitating one-lung ventilation (OLV). We encountered a highly unusual complication: contralateral tension pneumothorax. Forty-five minutes into the surgical procedure, a sudden cardiovascular collapse occurred.
View Article and Find Full Text PDFJ Vasc Interv Radiol
January 2025
Department of Vascular and Interventional Radiology, Singapore General Hospital, Outram Rd, Singapore 169608, Singapore.
Purpose: To investigate the feasibility of a robotic system with artificial intelligence-based lesion detection and path planning for CT-guided biopsy, compared to the conventional freehand technique.
Materials And Methods: Eight nodules within an abdominal phantom, incorporating the simulated vertebrae and ribs, were designated as targets. A robotic system was used for lesion detection, trajectory generation, and needle-holder positioning.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!