Background: The slope-intercept method is widely used for the determination of the plasma clearance of 51Cr-EDTA. When three or more plasma samples are used, the goodness-of-fit (r2) can be used as a measure of consistency of the samples. This parameter can not be used, however, if only two samples are available.

Purpose: To evaluate whether the single-sample technique (SBS) can be used to check the consistency of the slope-intercept method using two blood samples (2BS) in children.

Methods: Simulated computer models of a mono-exponential curve were created in order to represent three children aged 3, 6 and 10 years, each with a large range of clearances values and three distribution volumes, respectively 20%, 25% and 30% of body weight. Errors were then introduced in the injected dose (errors from -50% to +50%) and on the 120 or 240 min blood sample (errors from -50% to +50%). The effects of these errors on the clearance measurement using 2BS and SBS methods were calculated and compared.

Results: The errors on the injected dose, the 120 min and 240 min plasma samples introduced errors in the same direction and with the same magnitude on both the SBS and 2BS clearance values. For that reason, the comparison between the SBS methods and the 2BS techniques has a low sensitivity in detecting an eventual error. Striking differences between the SBS method and the 2BS technique were only observed when considerable errors on the injected dose or plasma samples were introduced, particularly in case of a reduced clearance. The comparison between the SBS clearances calculated using the 120 min sample to that obtained using the 240 min samples is slightly more sensitive. However, this approach is also slightly less specific. A difference of more than 10 ml . min(-1). 1.73 m(-2) can be observed in the absence of an error.

Conclusions: The use of the SBS for checking the consistency of the 2BS constitutes an insensitive approach to detect an eventual error in the injected dose or in the plasma samples. Obvious different results obtained by SBS and 2BS or between the SBS calculated using the 120 min and the 240 min samples suggest the presence of an error, but comparable results do not exclude erroneous measurement. Moreover, a difference of more than 10 ml . min(-1). 1.73 m(-2) can be observed in the absence of an error in the injected dose or in the plasma samples.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0b013e3280116ebaDOI Listing

Publication Analysis

Top Keywords

plasma samples
20
injected dose
20
240 min
16
slope-intercept method
12
120 min
12
dose plasma
12
samples
11
sbs
9
checking consistency
8
blood samples
8

Similar Publications

Background: Rex rabbit is famous for its silky and soft fur coat, a characteristic predominantly attributed to its hair follicles. Numerous studies have confirmed the crucial roles of mRNAs and non-coding RNAs (ncRNAs) in regulating key cellular processes such as cell proliferation, differentiation, apoptosis and immunity. However, their involvement in the regulation of the hair cycle in Rex rabbits remains unknown.

View Article and Find Full Text PDF

Objectives: we evaluated the hypothesis that level of ctHPVDNA on the first postoperative day (POD-1); and at 15 days (POD-15) could be associated with the need for adjuvant therapy and the presence of recurrence.

Materials And Methods: this is a prospective observational study on biomarkers, focusing on the longitudinal monitoring of ctHPVDNA in a cohort of HPV-OPSCC patients undergoing TORS. Blood samples were collected according to the following schema: (1) pretreatment; (2) on first postoperative day (POD 1); and (3) at 15 days (POD 15).

View Article and Find Full Text PDF

Magnetic nanoparticles of Nd2Fe14B prepared by ethanol-assisted wet ball milling technique.

Sci Rep

January 2025

Environmental and Occupational Hazards Control Research Center, Research Institute for Health Sciences and Environment, Shahid Beheshti University of Medical Sciences, Tehran, Iran.

The magnetic material Nd2Fe14B is one of the strongest magnetic materials found in nature. The demand for the production of these nanoparticles is significantly high due to their exceptional properties. The aim of the present study is to synthesize magnetic nanoparticles of Nd2Fe14B using ethanol in the wet ball milling technique (WBMT).

View Article and Find Full Text PDF

Background: Protein abundance levels, sensitive to both physiological changes and external interventions, are useful for assessing the Alzheimer's disease (AD) risk and treatment efficacy. However, identifying proteomic prognostic markers for AD is challenging by their high dimensionality and inherent correlations.

Methods: Our study analyzed 1128 plasma proteins, measured by the SOMAscan platform, from 858 participants 55 years and older (mean age 63 years, 52.

View Article and Find Full Text PDF

Immune checkpoint inhibitor (ICI) therapy is a cornerstone treatment for many cancers, but it can induce severe immunotoxicity, including acute interstitial nephritis (AIN). Currently, kidney biopsy is required to differentiate ICI-AIN from other causes of acute kidney injury (AKI). However, this invasive approach can lead to morbidity, delayed glucocorticoid treatment for patients with AIN, and unnecessarily prolonged suspension of ICI therapy in non-AIN patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!