Admission temperatures following radiant warmer or incubator transport for preterm infants <28 weeks: a randomised study.

Arch Dis Child Fetal Neonatal Ed

Neonatal Unit, Middlemore Hospital and University of Auckland, Hospital Road, Auckland, New Zealand .

Published: July 2007

AI Article Synopsis

Article Abstract

Sixty two infants <28 weeks were occlusively wrapped and randomised to radiant warmer or incubator transport to the neonatal unit. Median axillary temperature on arrival was 36.8 degrees C in both groups. Target temperatures (36.5-37.5 degrees C) were achieved in 60% of the incubator group compared to 75% in the warmer group (not statistically significant). While powered to detect a 35% difference between warming devices, a more modest difference is not excluded.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2675433PMC
http://dx.doi.org/10.1136/adc.2006.107128DOI Listing