Background: The reported diagnostic accuracy of the D-dimer test for exclusion of deep vein thrombosis (DVT) and pulmonary embolism (PE) varies. It is unknown to what extent this is due to differences in study design or patient groups, or to genuine differences between D-dimer assays.
Methods: Studies evaluating the diagnostic accuracy of the D-dimer test in the diagnosis of venous thromboembolism were systematically searched for in the MEDLINE and EMBASE databases up to March 2005. Reference lists of all included studies and of reviews related to the topic of the present meta-analysis were manually searched for other additional potentially eligible studies. Two reviewers independently extracted study characteristics using standardized forms.
Results: In total, 217 D-dimer test evaluations for DVT and 111 for PE were analyzed. Several study design characteristics were associated with systematic differences in diagnostic accuracy. After adjustment for these features, the sensitivities of the D-dimer enzyme-linked immunofluorescence assay (ELFA) (DVT 96%; PE 97%), microplate enzyme-linked immunosorbent assay (ELISA) (DVT 94%; PE 95%), and latex quantitative assay (DVT 93%; PE 95%) were superior to those of the whole-blood D-dimer assay (DVT 83%; PE 87%), latex semiquantitative assay (DVT 85%; PE 88%) and latex qualitative assay (DVT 69%; PE 75%). The latex qualitative and whole-blood D-dimer assays had the highest specificities (DVT 99%, 71%; PE 99%, 69%).
Conclusions: Compared to other D-dimer assays, the ELFA, microplate ELISA and latex quantitative assays have higher sensitivity but lower specificity, resulting in a more confident exclusion of the disease at the expense of more additional imaging testing. These conclusions are based on the most up-to-date and extensive systematic review of the topic area, including 184 articles, with 328 D-dimer test evaluations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1538-7836.2007.02328.x | DOI Listing |
Rev Cardiovasc Med
January 2025
Thoracic Clinical College, Tianjin Medical University, 300070 Tianjin, China.
Background: Studies using machine learning to identify the target characteristics and develop predictive models for coronary artery disease severity in patients with premature myocardial infarction (PMI) are limited.
Methods: In this observational study, 1111 PMI patients (≤55 years) at Tianjin Chest Hospital from 2017 to 2022 were selected and divided according to their SYNTAX scores into a low-risk group (≤22) and medium-high-risk group (>22). These groups were further randomly assigned to a training or test set in a ratio of 7:3.
Medicina (Kaunas)
December 2024
Department of Internal Medicine, Hospital Universitario Infanta Leonor-Virgen de la Torre, 28031 Madrid, Spain.
: Venous thromboembolism (VTE) can be the first manifestation of an underlying cancer. This study aimed to develop a predictive model to assess the risk of occult cancer between 30 days and 24 months after a venous thrombotic event using machine learning (ML). : We designed a case-control study nested in a cohort of patients with VTE included in a prospective registry from two Spanish hospitals between 2005 and 2021.
View Article and Find Full Text PDFJ Vasc Access
January 2025
Department of Nephrology, University of Electronic Science and Technology of China Sichuan Provincial People's Hospital, Chengdu, China.
Objective: The primary objective of this study is to develop and validate a high-risk model for Arteriovenous Fistula Thrombosis (AVFT) in patients undergoing autogenous arteriovenous fistula surgery for hemodialysis.
Methods: Retrospectively, we collected general information, clinical characteristics, laboratory examinations, and dialysis-related factors from a cohort of 1465 patients who received continuous arteriovenous fistula surgery at the Hemodialysis Access Center of Sichuan Provincial People's Hospital between January 2019 and June 2022. The patients were randomly divided into a training set and a validation set in a 2:1 ratio.
Front Neurosci
January 2025
Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea.
Introduction: Delirium, frequently experienced by ischemic stroke patients, is one of the most common neuropsychiatric syndromes reported in the Intensive Care Unit (ICU). Stroke patients with delirium have a high mortality rate and lengthy hospitalization. For these reasons, early diagnosis of delirium in the ICU is critical for better patient prognosis.
View Article and Find Full Text PDFCureus
December 2024
Nursing & Midwifery Research, Hamad Medical Corporation, Doha, QAT.
Pulmonary embolism (PE) is a critical condition that arises when clots migrate to the lungs, obstructing pulmonary circulation and posing a significant risk to the patient's health. While the D-dimer test is useful for excluding PE, it is not infallible. This report describes a case where extensive PE was present despite the patient having a normal D-dimer level, emphasizing the importance of a thorough clinical evaluation.