The comparability of recall performance was examined on the Rey-Osterrieth Complex Figure, the Taylor Complex Figure, and the Modified Taylor Complex Figure as measures of visuospatial abilities and visual memory in 66 healthy Japanese university students. A between-subjects design was used in which each of the participants received the three figures. The interrater reliability of each was excellent. While the three figures yielded equivalent copy scores, the Taylor Complex Figure produced significantly higher scores than the other two on both short (3-min.) and delayed (30-min.) recall tests. There were no significant differences between recall scores of the Rey-Osterrieth and the Modified Taylor figures. These results are consistent with the findings of the 2002 study of English-speakers by Hubley and Tremblay, and support that the Modified Taylor Figure is superior to the original one for the companion figure to the Rey-Osterrieth Complex Figure.

Download full-text PDF

Source
http://dx.doi.org/10.2466/pr0.99.2.531-534DOI Listing

Publication Analysis

Top Keywords

complex figure
32
taylor complex
20
modified taylor
16
rey-osterrieth complex
12
figure
10
complex
8
figure taylor
8
figure modified
8
three figures
8
taylor
7

Similar Publications

Minimally invasive biomarkers for triaging lung nodules-challenges and future perspectives.

Cancer Metastasis Rev

January 2025

Saliva and Liquid Biopsy Translational Laboratory, Institute for Biomedicine and Glycomics (IBG), Griffith University, Brisbane, 4111, Australia.

CT chest scans are commonly performed worldwide, either in routine clinical practice for a wide range of indications or as part of lung cancer screening programs. Many of these scans detect lung nodules, which are small, rounded opacities measuring 8-30 mm. While the concern about nodules is that they may represent early lung cancer, in screening programs, only 1% of such nodules turn out to be cancer.

View Article and Find Full Text PDF

Electromagnetic wave absorption materials that can be utilized for freewill adhering or peeling from the target substrate remain a challenge to be solved. Compared to powder-based slurry and coatings, microwave absorption films possess clear advantages for their good flexibility and machinability. However, the matching thickness and effective bandwidth of 2D microwave absorption films cannot satisfy the current application requirements.

View Article and Find Full Text PDF

Significant Radiation Reduction Using Cloud-Based AI Imaging in Manually Matched Cohort of Complex Aneurysm Repair.

Ann Vasc Surg

January 2025

Division of Vascular & Endovascular Surgery, Weill Cornell Medicine, New York, NY. Electronic address:

Objective: Cloud-based, surgical augmented intelligence (Cydar Medical, Cambridge, UK) can be used for surgical planning and intraoperative imaging guidance during complex endovascular aortic procedures. We aim to evaluate radiation exposure, operative safety metrics, and post-operative renal outcomes following implementation of Cydar imaging guidance using a manually matched cohort of aortic procedures.

Methods: We retrospectively reviewed our prospectively maintained database of endovascular aortic cases.

View Article and Find Full Text PDF

Background: Attention-Deficit Hyperactivity Disorder (ADHD) is a complex disease that negatively impacts the social and academic/occupational activities of children and is more common in boys than in girls.

Methods: This case-control study aimed to assess the association between some environmental risk factors and ADHD among children in Alexandria, Egypt. It was carried out at the outpatient clinics of El Shatby Pediatric University Hospital in Alexandria, Egypt, with 252 children (126 cases and 126 controls).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!