Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: This study used intraoperative monitoring of the access flow to evaluate the results of flow reduction in the management of high-flow arteriovenous access-related symptoms of distal ischemia and cardiac insufficiency.
Methods: A retrospective study was conducted of 95 patients (78 with ischemia, 17 with cardiac failure) who underwent flow reduction between 1999 and 2005. A preoperatively measured access flow-volume rate > 800 mL/min for autogenous accesses (n = 77) and > 1200 mL/min for prosthetic accesses (n = 18) was the selection criterion for the use of a flow reduction procedure. Flow reduction was achieved using a spindle-like narrowing suture near the anastomosis and final placement of a polytetrafluoroethylene strip while a flow meter was used for intraoperatively measuring the access flow. The desired postoperative flow was 400 mL/min for autogenous and 600 mL/min for prosthetic accesses.
Results: The mean preoperative access flow was 1469 +/- 633 mL/min in patients with ischemia and 2084 +/- 463 mL/min in patients with cardiac failure, without significant differences between access types. The flow was reduced to 499 +/- 175 mL/min for autogenous accesses and to 676 +/- 47 mL/min for prosthetic accesses. The mean follow-up was 25 months (range, 1 to 73 months). Complete long-term relief of symptoms was observed in 86% of patients with ischemia and in 96% of patients with cardiac failure. Reconstruction significantly increased the digital-brachial index (0.41 +/- 0.12 vs 0.74 +/- 0.11; P < .05) and mean distal arterial pressure (47 +/- 17 mm Hg vs 79 +/- 21 mm Hg; P < .05) in patients with ischemia. Primary patency rates were significantly better for reconstructed autogenous accesses compared with rates of prosthetic accesses (91% +/- 4% vs 58% +/- 12% at 12 months; 81% +/- 6% vs 41% +/- 14% at 36 months; P < .001). The low patency of reconstructed prosthetic accesses is due to the high thrombosis risk of accesses that have a flow < 700 mL/min.
Conclusions: Flow reduction using intraoperative access flow monitoring is an effective and durable technique allowing for the correction of distal ischemia and cardiac insufficiency in patients with a high-flow autogenous access. The desired postoperative access flow of 400 mL/min is not associated with an increased risk of thrombosis. Flow reduction of prosthetic access is as effective; however, a higher access flow than the desired 600 mL/min seems to be necessary to achieve an acceptable patency in prosthetic accesses.