A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Chronically recording with a multi-electrode array device in the auditory cortex of an awake ferret. | LitMetric

Chronically recording with a multi-electrode array device in the auditory cortex of an awake ferret.

J Neurosci Methods

Department of Anatomy and Neurobiology, Program in Neuroscience, School of Medicine, University of Maryland, Baltimore, MD 21201, USA.

Published: March 2007

It is known that anesthesia depresses neural activity and inhibits cortico-cortical interactions and cortical output. Hence, it is important to record from awake animals in order to better understand the full dynamic range of neural responses. We have developed a preparation for chronic, multi-electrode physiological recording in the cortex of the awake ferret. This paper discusses several of the advantages and disadvantages of the technique as well as procedures used to overcome potential complications associated with chronic implants in the ferret. Our solutions are well suited to the special species requirements, yet are also easily generalizable to other species.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1955228PMC
http://dx.doi.org/10.1016/j.jneumeth.2006.10.013DOI Listing

Publication Analysis

Top Keywords

cortex awake
8
awake ferret
8
chronically recording
4
recording multi-electrode
4
multi-electrode array
4
array device
4
device auditory
4
auditory cortex
4
ferret anesthesia
4
anesthesia depresses
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!