300 microJ noncollinear optical parametric amplifier in the visible at 1 kHz repetition rate.

Opt Lett

Max Born Institte for Nonlinear Optics and Shory Pulse Spectroscopy, Max-Born-Strasse 2A, Berlin, Germany.

Published: December 2006

We demonstrate an order-of-magnitude energy scaling of a white-light seeded noncollinear optical parametric amplifier in the visible. The generated pulses, tunable between 520 and 650 nm with sub-25-fs duration, had energies up to 310 microJ with 20% blue-pump-to-signal energy conversion efficiency at 540 nm. This new ultrafast source will make possible numerous extreme nonlinear optics applications. As a first application, we demonstrate the generation of tunable vacuum ultraviolet pulses.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.31.003629DOI Listing

Publication Analysis

Top Keywords

noncollinear optical
8
optical parametric
8
parametric amplifier
8
amplifier visible
8
300 microj
4
microj noncollinear
4
visible khz
4
khz repetition
4
repetition rate
4
rate demonstrate
4

Similar Publications

Spintronic devices and applications using noncollinear chiral antiferromagnets.

Nanoscale Horiz

December 2024

Electrical and Computer Engineering, The Grainger College of Engineering, University of Illinois Urbana-Champaign, Urbana, USA.

Antiferromagnetic materials have several unique properties, such as a vanishingly small net magnetization, which generates weak dipolar fields and makes them robust against perturbation from external magnetic fields and rapid magnetization dynamics, as dictated by the geometric mean of their exchange and anisotropy energies. However, experimental and theoretical techniques to detect and manipulate the antiferromagnetic order in a fully electrical manner must be developed to enable advanced spintronic devices with antiferromagnets as their active spin-dependent elements. Among the various antiferromagnetic materials, conducting antiferromagnets offer high electrical and thermal conductivities and strong electron-spin-phonon interactions.

View Article and Find Full Text PDF

Infrared imaging of magnetic octupole domains in non-collinear antiferromagnets.

Natl Sci Rev

June 2024

International Center for Quantum Design of Functional Materials (ICQD), School of Emerging Technology, University of Science and Technology of China, Hefei 230026, China.

Article Synopsis
  • The study highlights the importance of magnetic structure in antiferromagnets (AFMs), emphasizing their potential for digital data encoding and novel physical phenomena.
  • Despite their significance, visualizing the domain structure of non-collinear AFMs remains challenging, with current methods limited to materials like MnSn.
  • The researchers introduce a new imaging technique using the anomalous Ettingshausen effect (AEE) that allows for simultaneous observation of magnetic domains in various non-collinear AFMs, enhancing understanding of their magnetization processes.
View Article and Find Full Text PDF

Emergent Skyrmions in CrTe nanoflakes at Room Temperature.

Small

December 2024

Center for Spintronics and Quantum Systems, State Key Laboratory for Mechanical Behavior of Materials, School of Materials Science and Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.

Chiral noncollinear magnetic nanostructures, such as skyrmions, are intriguing spin configurations with significant potential for magnetic memory technologies. However, the limited availability of 2D magnetic materials that host skyrmions with Curie temperatures above room temperature presents a major challenge for practical implementation. Chromium tellurides exhibit diverse spin configurations and remarkable stability under ambient conditions, making them a promising platform for fundamental spin physics research and the development of innovative 2D spintronic devices.

View Article and Find Full Text PDF

Light pulses in the femtosecond range require sophisticated methods for their precise temporal characterization. Several techniques have been developed over the past decades that deliver the temporal structure of ultrashort light pulses. Still, there are special cases left that cannot be treated directly by established methods.

View Article and Find Full Text PDF

Computational Mueller matrix polarimetry holds great promise in biomedical studies and clinical applications, providing comprehensive polarization-related vectorial information within the sample. For backscattering polarization imaging systems aimed at in vivo tissue polarimetry, the measurement results can be affected by the Cartesian coordinates transformation due to the vectorial properties of polarized light and the non-collinear characteristics of the measurement system. It can influence the reliability of polarization information decoding and extraction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!