A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Structure of high-performance evaporators for space application. | LitMetric

Structure of high-performance evaporators for space application.

Ann N Y Acad Sci

Department of Aeronautics and Astronautics, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0359, Japan.

Published: September 2006

A new structure of cold plates, where an unheated auxiliary channel is installed to supply liquid directly to the bottom of coalesced flattened bubbles in a narrow heated channel, is tested to investigate the increase in critical heat flux. Assuming the application to the laser solar power system, a large heating surface with a length of 150 mm in the flow direction is employed, and a narrow channel structure is adopted to reduce the size of cold plates, where the gap sizes are selected as 5 mm and 2 mm. Experiments are performed for water as a test liquid at inlet subcooling of 15 K under near atmospheric pressure. Inlet liquid velocity is varied from 0.065 m/s to 0.6m/s for the upward flow on ground. A value of critical heat flux of 2.2 x 10(6) W/m2 is obtained for 5-mm gap size at the inlet velocity of 0.2 m/s. At low liquid flow rate, the structure realizes the CHF values larger by 2.5 times than those for the normal heated channel without additional liquid supply. A new method to evaluate the performance of cold plates is proposed to take account of the variation in the size of heating surface, inlet liquid velocity, and subcooling that influence the CHF values. The validity of the proposed structure of the cold plate for the increase in critical heat flux is confirmed.

Download full-text PDF

Source
http://dx.doi.org/10.1196/annals.1362.015DOI Listing

Publication Analysis

Top Keywords

cold plates
12
critical heat
12
heat flux
12
structure cold
8
heated channel
8
increase critical
8
heating surface
8
inlet liquid
8
liquid velocity
8
chf values
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!