A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mechanism of effective nocardioform foam control measures for non-selector activated sludge systems. | LitMetric

Mechanism of effective nocardioform foam control measures for non-selector activated sludge systems.

Water Environ Res

Wastewater Enterprise, Public Utilities Commission, San Francisco, CA 94124, USA.

Published: September 2006

Solids retention time (SRT), biological scum trapping and recycle, and the dynamic equilibrium between Nocardioform populations in the foam and the mixed liquor are the controlling factors in activated sludge foaming events caused by Nocardioform bacteria. For the operating modes described in this paper, a cured mixed liquor foaming condition (filament counts of approximately 10(5) intersections/g volatile suspended solids) was only achieved when SRT control, selective wasting, and polymer addition were in effect. Solids retention time control, with the SRT remaining below 1.5 days, and selective wasting will cure a severely foaming mixed liquor, but effects will only be observed after 3 or 4 months after implementation. The combined wastage of Nocardioform bacteria from selective wasting and SRT control can ensure long-term foam control to the operation of a pure-oxygen activated sludge system with foam-trapping features. An SRT of 0.3 days will result in the complete washout of Nocardioform bacteria from the activated sludge system, which can then operate at an SRT of 3 days free of Nocardioform. Polymer addition to mixed liquor is only effective for foam control when a large portion of the system biomass exists as a heavy layer of foam above the mixed liquor.

Download full-text PDF

Source
http://dx.doi.org/10.2175/106143005x72993DOI Listing

Publication Analysis

Top Keywords

mixed liquor
20
activated sludge
16
foam control
12
nocardioform bacteria
12
selective wasting
12
solids retention
8
retention time
8
foam mixed
8
srt control
8
polymer addition
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!