A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. | LitMetric

Objectives: We sought to determine the diagnostic performance of whole-heart coronary magnetic resonance (MR) angiography for detecting significant coronary artery disease.

Background: The accuracy of whole-heart coronary MR angiography has not been determined in a large number of patients.

Methods: Three-dimensional coronary MR angiograms covering the entire heart were obtained during free breathing in 131 patients. Images were acquired during a patient-specific time window in the cardiac cycle with minimal motion of the coronary artery. Significant coronary artery disease was defined on X-ray coronary angiography as a diameter reduction of > or =50% in coronary arteries with a reference diameter of > or =2 mm.

Results: The acquisition of MR angiography was completed in 113 (86%) of 131 patients, with an imaging time averaged at 12.9 +/- 4.3 min. On a patient-based analysis, the sensitivity, specificity, positive and negative predictive value, and accuracy of MR angiography were 82% (95% confidence interval [CI] 69% to 91%), 90% (95% CI 79% to 96%), 88% (95% CI 74% to 95%), 86% (95% CI 75% to 93%), and 87% (95% CI 79% to 92%), respectively. These values in the individual segments were 78% (95% CI 68% to 85%), 96% (95% CI 95% to 97%), 69% (95% CI 60% to 77%), 98% (95% CI 96% to 98%), and 94% (95% CI 96% to 96%).

Conclusions: Whole-heart coronary MR angiography allows for noninvasive detection of significant narrowing in coronary arterial segments with a diameter of > or =2 mm with moderate sensitivity and high specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2006.07.055DOI Listing

Publication Analysis

Top Keywords

coronary artery
16
whole-heart coronary
16
coronary angiography
12
95%
12
coronary
11
coronary magnetic
8
magnetic resonance
8
resonance angiography
8
131 patients
8
95% 79%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!