A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of 90Sr in contaminated environmental samples by tuneable bandpass dynamic reaction cell ICP-MS. | LitMetric

Determination of 90Sr in contaminated environmental samples by tuneable bandpass dynamic reaction cell ICP-MS.

Anal Bioanal Chem

Environmental and Resources Studies, Trent University, Peterborough, ON, K9J 7B8, Canada.

Published: January 2007

A rapid method for the extraction and determination of 90Sr in natural water, plant and sediment samples was developed using extraction chromatography and dynamic reaction cell ICP-MS, with O2 as a reaction gas. While isobaric interference from the stable isotope 90Zr was efficiently removed by this method, interferences produced from in-cell reactions with Fe+ and Ni+ required suppression by tuneable bandpass, and in sediments, additional chromatographic separation. Method detection limits were 0.1 pg g-1 (0.5 Bq g-1), 0.04 pg g-1(0.2 Bq g-1), and 3 pg L-1 (5 Bq L-1) for sediments, plant and water samples, respectively, and 90Sr concentrations determined by ICP-MS were in good agreement with activities determined by Cerenkov counting and with certified reference values. While mass spectrometric determination does not rival detection limits achievable by radiometric counting, radiometric determination of 90Sr, a pure beta-emitter, is hindered by long analysis times (several weeks); the comparatively fast analysis achieved via ICP-MS enables same-day preparation and analysis of samples, making this an important technique for the environmental monitoring of areas contaminated by radioactivity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-006-0938-8DOI Listing

Publication Analysis

Top Keywords

determination 90sr
12
tuneable bandpass
8
dynamic reaction
8
reaction cell
8
cell icp-ms
8
detection limits
8
determination
4
90sr contaminated
4
contaminated environmental
4
samples
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!