A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter. | LitMetric

Background: Treatment of coronary in-stent restenosis is hampered by a high incidence of recurrent in-stent restenosis. We assessed the efficacy and safety of a paclitaxel-coated balloon in this setting.

Methods: We enrolled 52 patients with in-stent restenosis in a randomized, double-blind, multicenter trial to compare the effects of a balloon catheter coated with paclitaxel (3 microg per square millimeter of balloon surface area) with those of an uncoated balloon catheter in coronary angioplasty. The primary end point was late luminal loss as seen on angiography. Secondary end points included the rates of restenosis (a binary variable) and major adverse cardiac events.

Results: Multivessel disease was present in 80% of patients in both groups. Quantitative coronary angiography revealed no significant differences in baseline measures. At 6 months, angiography showed that the mean (+/-SD) in-segment late luminal loss was 0.74+/-0.86 mm in the uncoated-balloon group versus 0.03+/-0.48 mm in the coated-balloon group (P=0.002). A total of 10 of 23 patients (43%) in the uncoated-balloon group had restenosis, as compared with 1 of 22 patients (5%) in the coated-balloon group (P=0.002). At 12 months, the rate of major adverse cardiac events was 31% in the uncoated-balloon group and 4% in the coated-balloon group (P=0.01). This difference was primarily due to the need for target-lesion revascularization in six patients in the uncoated-balloon group (P=0.02).

Conclusions: Treatment of coronary in-stent restenosis with paclitaxel-coated balloon catheters significantly reduced the incidence of restenosis. These data suggest that the inhibition of restenosis by local drug delivery may not require stent implantation and sustained drug release at the site of injury. (ClinicalTrials.gov number, NCT00106587 [ClinicalTrials.gov].).

Download full-text PDF

Source
http://dx.doi.org/10.1056/NEJMoa061254DOI Listing

Publication Analysis

Top Keywords

in-stent restenosis
20
uncoated-balloon group
16
treatment coronary
12
coronary in-stent
12
paclitaxel-coated balloon
12
balloon catheter
12
coated-balloon group
12
restenosis
9
restenosis paclitaxel-coated
8
late luminal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!