Reference databases play a key role in the management of osteoporosis. The aim of this preliminary study was to compare the diagnostic consequences of using either an international or a local reference database in peripheral densitometry. For this purpose, standard curves for bone mineral density (measured by dual-energy X-ray absorptiometry at the distal and proximal forearm) were generated for healthy Hungarian men and women. In total, 303 healthy volunteers of both sexes (age range: 20-94 yr) were recruited from four osteoporosis centers. Subjects with medical conditions or taking medication affecting the bone metabolism were excluded. Bone densitometry was performed with pDEXA (Norland-Stratec, Fort Atkinson, WI) devices in each center after cross-calibration of the machines. The precision error of the forearm measurement was also determined (<1% in vitro, and 1.2-2.5% in vivo). In females, the peak forearm density was detected in the 30-39-yr group. The density decreased by 8% per 5 yr in early postmenopausal females, and by 10% per 10 yr in late postmenopausal females. In males, the highest bone mineral density was found in the 30-39-yr group for the distal forearm, but 1 decade later for the proximal site. Subsequently, a 5% decrease in density occurred per 10 yr, except in the 8th decade, in which a 20% decrease was demonstrated. One thousand four hundred thirty-four patients with suspected osteoporosis were classified according to the forearm density T-scores using both the new Hungarian reference database and the international database provided by the manufacturer. Comparison of the results measured at the distal forearm with the two different databases led to similar outcomes. However, at the proximal site, one fifth of the female patients were reclassified from the low-density group to the normal group using the domestic normative database. An opposite difference was observed for the males: use of the Hungarian reference data resulted in 40% more men being categorized in the low-density group than when the international normal database was applied. Our results suggest that not only geographic differences, but also the reference database used, can influence the prevalence of the diagnosis of osteoporosis. Further data are currently being collected to increase the statistical power of the study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocd.2006.06.004DOI Listing

Publication Analysis

Top Keywords

reference databases
8
comparative evaluation
4
evaluation local
4
local international
4
international reference
4
databases forearm
4
forearm densitometry
4
densitometry impacts
4
impacts diagnostic
4
diagnostic decisions
4

Similar Publications

The Zika virus (ZIKV), an arbovirus within the Flavivirus genus, is associated with severe neurological complications, including Guillain-Barré syndrome in affected individuals and microcephaly in infants born to infected mothers. With no approved vaccines or antiviral treatments available, there is an urgent need for effective therapeutic options. This study aimed to identify new natural compounds with inhibitory potential against the NS2B-NS3 protease (PDB ID: 5LC0), an essential enzyme in viral replication.

View Article and Find Full Text PDF

Focusing on the Yashkun population of Gilgit-Baltistan, an administrative territory in northern Pakistan, our study investigated mtDNA haplotypes as indicators of ancient gene flow and genetic diversity. Genomic DNA was extracted and evaluated for quality using agarose gel electrophoresis. The complete control region of mtDNA (nt 16024-576) was amplified via PCR, and sequencing was performed using the Big Dye Terminator Kit on an Applied Biosystems Genetic Analyzer.

View Article and Find Full Text PDF

Introduction: Continued interest in the optimization of recovery in aesthetics has led to the exploration of adjunctive therapies. Hyperbaric oxygen therapy (HBOT) serves as one such therapy that may have an impact in this field. HBOT is hypothesized to improve ischemia, reduce swelling, and minimize secondary hypoxic tissue damage.

View Article and Find Full Text PDF

A stable combination of non-stable genes outperforms standard reference genes for RT-qPCR data normalization.

Sci Rep

December 2024

Laboratoire de Recherche en Sciences Végétales, Equipe Génomique et Biotechnologie des Fruits, UMR 5546, CNRS, UPS, Toulouse INP, Université de Toulouse, Toulouse, France.

Gene expression profiling is of key importance in all domains of life sciences, as medicine, environment, and plants, for both basic and applied research. Despite the emergence of microarrays and high-throughput sequencing, qPCR remains a standard method for gene expression analyses, with its data normalization step being crucial for ensuring accuracy. Currently, the most widely used normalization method is based on the use of reference genes, assumed to be stably expressed across all experimental conditions.

View Article and Find Full Text PDF

As molecular research on hemp (Cannabis sativa L.) continues to advance, there is a growing need for the accumulation of more diverse genome data and more accurate genome assemblies. In this study, we report the three-way assembly data of a cannabidiol (CBD)-rich cannabis variety, 'Pink Pepper' cultivar using sequencing technology: PacBio Single Molecule Real-Time (SMRT) technology, Illumina sequencing technology, and Oxford Nanopore Technology (ONT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!