Ultra-sonic bone surgery (USBS) has been recently introduced as a novel osteotomic technique. This clinical study reports on the application of this new technique to perform ridge-split procedures. Over a period of 3.5 years, 57 patients underwent a split-crest procedure with the aim to place 230 implants, 78 in the mandible and 152 in the maxilla, in order to rehabilitate nine full arches, three hemi-arcades, 43 partial bridges and 24 single crowns. The initial ridge width varied between 1.5 and 5 mm, average was 3.2 mm. The final width of the ridge ranged from 4 to 9 mm, average was 6 mm. The split length varied between 4.5 and 40 mm, average was 15 mm. Inserted implants were 3.25-5 mm in diameter however most of them (82.4%) were standard implants of 3.75 mm; implant length was classically 10-13 mm. Two hundred and twenty-eight (99.1%) out of the 230 planned implants were placed, the two non-suitable sites were in the maxilla. In the mandible, the ridge augmentation procedure was drastically eased by performing a basal longitudinal discharge notch. At second stage surgery, eight implants failed to osseointegrate; the success rate for the placed implants was 96.5%. All implants have been loaded for at least 2 months and no implant was lost after loading. One hundred and eighty-one and 77 implants have been loaded for at least 6 and 12 months, respectively. The 3-year life-table analysis of loaded implants showed a cumulative survival rate of 100%. The split-crest procedure performed with USBS showed to be safe and comfortable.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0501.2006.01206.xDOI Listing

Publication Analysis

Top Keywords

implants
9
ultra-sonic bone
8
bone surgery
8
3-year life-table
8
life-table analysis
8
split-crest procedure
8
varied average
8
implants loaded
8
loaded months
8
split-crest implant
4

Similar Publications

Where does the tether break in vertebral body tethering cases? Clinical insights from revision cases after tether breakage.

Spine Deform

January 2025

Department of Spine Surgery, Eifelklinik St Brigida, St. Brigida Eifelklinik, Kammerbruchst. 8, 52152, Simmerath, Germany.

Purpose: To evaluate the sites where the tether breaks in vertebral body tethering (VBT) cases.

Methods: Intraoperative evaluation of broken tethers in patients who had anterior revision.

Inclusion Criteria: anterior revision of VBT cases with explantation of the full implant and photo documentation.

View Article and Find Full Text PDF

Prognosis of Implant-Based Breast Reconstruction After Mastectomy Flap Necrosis: Predictors of Failure and Salvage.

Aesthetic Plast Surg

January 2025

Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea.

Background: In the realm of implant-based breast reconstruction, mastectomy flap necrosis (MFN) is a prevalent yet grave complication that poses a threat to the stability of the inserted prosthesis. Although numerous investigations have scrutinized the risk factors for MFN development, few have delved into the aftermath, specifically implant failure or salvage. This study seeks to appraise the prognosis of the implanted prosthesis following MFN occurrence, as well as identify predictors of such outcomes.

View Article and Find Full Text PDF

Comprehensive multimodal imaging is essential for the precise clinical diagnostics of neovascular age-related macular degeneration (nAMD). Noninvasive optical coherence tomography (OCT) is of prime importance regarding the baseline examination, follow-up and monitoring during treatment. The OCT imaging in nAMD eyes enables a high-resolution assessment of the retinal micromorphology, which can be considerably disturbed in different layers.

View Article and Find Full Text PDF

Short-term outcomes of mesh-suture repair in the treatment of ventral hernias: a single-center study.

Surg Endosc

January 2025

Division of Minimally Invasive and Bariatric Surgery, Penn State Health Milton S. Hershey Medical Center, 500 University Drive, Hershey, PA, 17033, USA.

Background: Defect closure with mesh suture is a novel technique for hernia repair. Originally described as the construction of lightweight macroporous polypropylene mesh strips as a suture material, it is now available as an FDA-approved product. Mesh suture better distributes tensile forces and reduces fascial tearing compared to traditional suture but requires less implanted material and tissue dissection compared to planar mesh.

View Article and Find Full Text PDF

Signaling pathway mechanisms of circadian clock gene Bmal1 regulating bone and cartilage metabolism: a review.

Bone Res

January 2025

Department of Orthodontics, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China.

Circadian rhythm is ubiquitous in nature. Circadian clock genes such as Bmal1 and Clock form a multi-level transcription-translation feedback network, and regulate a variety of physiological and pathological processes, including bone and cartilage metabolism. Deletion of the core clock gene Bmal1 leads to pathological bone alterations, while the phenotypes are not consistent.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!