Objectives: To explore applicable protocol for the positioning of ventricular septal defect (VSD) occluder and the selection of the device by retrospective analysis of transcatheter closure approach to the aneurysms of the perimembranous VSD.
Methods: Thirty-five cases of perimembranous VSD with septal aneurysm (19 males and 16 females) from May, 2004 to May, 2005 were included, with a mean age of 5.3 y and mean weight of 17.6 kg. Their angiographic and ultrasound data, and interventional processes were analyzed. Seven segments of the aneurysms were assessed: the diameter of the defect on the left ventricle, the diameter of the defect on the right ventricle, the thickness of ventricular septum, the distance from the farthest end of the aneurysm to the defect, the diameter of the widest part of the aneurysm and the distance between the two farthest orifices on the aneurysm.
Results: Sixteen cystiform aneurysms and nineteen tubiform ones were identified with left ventricular angiography. The diameters of the orifices of aneurysms and the diameters of the VSDs ranged from 1.5 mm to 4.1 mm and 2.7 mm to 11.9 mm, separately, with the mean of 2.9 mm and 4.3 mm. From the echocardiography, the distances of the rim of defect to the aortic valve ranged from 2.0 mm to 7.0 mm, with the mean of 4.3 mm. All the interventions were successfully done with symmetrical devices from 4 mm to 14 mm. The left disc of the device was positioned at the defect surface from the left ventricle in 29 cases, and was released at the left side of the orifice in 3 cases.
Conclusions: The positioning of the left disc is mostly determined by the condition for the correct formation of the right disc in the right ventricle after deploying. Generally the defect surface in the left ventricle is most ideal to release the left disc of the device. If the body of aneurysm was too long for the right disc to restore its configuration, the left disc should be released on the left side of the orifice. The selection of device size is determined by the placement of the left disc. When the left disc is to be released at the defect surface in the left ventricle, the device size should be equal to or 1 to 2 mm larger than the diameter of the defect on the left ventricle. When the left disc is to be deployed on the left side of an orifice, the device size should be equal to or 1 mm larger than the defect diameter on the left ventricle when there is a single orifice. In the case of multiple orifices, the minimal size of the device which can cover all the orifices should be selected.
Download full-text PDF |
Source |
---|
Front Bioeng Biotechnol
December 2024
Department of Orthopaedics, Peking University Third Hospital, Beijing, China.
Objective: To confirm the effect of surgery on spinal column biomechanics and to provide theoretical support for the advantages and disadvantages of different surgical methods and their clinical efficacy.
Methods: 33 continuous patients with no significant difference in risk factors related to the mechanical complications were enrolled in this retrospective study. Sagittal parameters were measured in the pre-, post-operative and following-up lateral radiograph of spine.
Zhongguo Gu Shang
December 2024
Derpartment of Spine Surgery, Nuclear Industry 416 Hospital, Chengdu 610000, Sichuan, China.
Objective: To explore feasibility, clinical and imaging outcomes of percutaneous endoscopic interlaminar discectomy (PEID) for single level large lumbar disc herniation(LDH).
Methods: From October 2018 to March 2023, 31 patients with single level LDH treated with PEID were retrospectively analyzed. Among patients, including 18 males and 13 females, aged from 15 to 40 years old with an average of (28.
J Med Case Rep
December 2024
Beijing Acupuncture and Chinese Herbology, 19 Edgemoor Road, Lutherville-Timonium, MD, 21093, USA.
Background: Magnetic therapy has demonstrated beneficial effects for reducing pain, nausea, neuropathy, and various other health concerns in the human body. To our knowledge, limited research has documented the use of auricular static magnetic therapy as a potential treatment for diabetes. This report presents the first evidence of using magnetic discs placed at acupuncture points on the human ear to decrease blood glucose levels and promote the healing of gangrene in diabetic patients.
View Article and Find Full Text PDFJ Neurosurg Case Lessons
December 2024
Department of Neurosurgery, Warren Alpert Medical School of Brown University, Providence, Rhode Island.
Background: Rotational vertebral artery occlusion, or bow hunter's syndrome (BHS), is a rare but clinically important cause of vertebrobasilar insufficiency. Extrinsic compression of the artery is usually caused by osteophytes, fibrous bands, or lateral disc herniation and typically occurs in the setting of anatomical variations, leading to dynamic compromise of the posterior circulation. Neoplastic causes of BHS are rare.
View Article and Find Full Text PDFOphthalmol Glaucoma
December 2024
Ruiz Department of Ophthalmology and Visual Science, McGovern Medical School at The University of Texas Health Science Center at Houston.
Objective: This study investigates the incidence and causes of diagnostic changes from primary open angle glaucoma suspect (POAGS) to primary open angle glaucoma (POAG), and vice versa, in clinical practice.
Design: This is a retrospective, single site, case-control study.
Participants: It includes patients over age 40 diagnosed with either POAG or POAGS between 2013-2020.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!