Purpose: To investigate the influence of composite resin consistency and placement technique on proximal contact tightness of Class II composite resin restorations.

Materials And Methods: A manikin model (KaVo Dental) was used with an artificial first molar in which a standardized MO preparation was ground. This preparation was duplicated 360 times. Cavities were restored using Clearfil Photo Bond (Kuraray) combined with one of three composite resins of different consistencies: a low-viscosity (X-Flow, Dentsply), a medium-viscosity (Clearfil AP-X, Kuraray) and a high-viscosity composite (Tetric Ceram HB, Ivoclar Vivadent). Each composite was combined with 6 different matrix systems and separation techniques (n = 20). Groups 1 and 2: precontoured metal circumferential matrix (KerrHawe 1101-c) in a Tofflemire retainer combined either with hand instrument (OptraContact, Ivoclar Vivadent) or separation ring (Composi-Tight Gold, Garrison Dental Solutions). Group 3: pre-contoured metal sectional matrix (Lite-Flex, Danville Materials) with separation ring. Groups 4 and 5: pre-contoured metal circumferential dead-soft matrix (Adapt SuperCap, KerrHawe) with or without separation ring. Group 6: flat metal circumferential matrix (OptraMatrix, Ivoclar Vivadent) in a Tofflemire-retainer with hand instrument (OptraContact). Proximal contact tightness was measured using the Tooth Pressure Meter (University of Technology, Delft). To determine the effect of experimental variables on the proximal contact tightness, a multiple linear regression model was constructed.

Results: Measurements in group 6 were not possible; therefore, this group was excluded. The use of medium- or high-viscosity instead of a low-viscosity composite resin resulted in statistically significantly tighter proximal contacts (p < 0.01). The use of a separation ring resulted in a large, statistically significant increase (p < 0.001) in contact tightness, while the use of a hand instrument resulted in a small, statistically significant increase of contact tightness (p = 0.017). No statistically significant differences were found when a dead-soft matrix or a sectional matrix was used instead of a Tofflemire (p = 0.159, p = 0.261, resp.).

Conclusion: Use of a separation ring when restoring a Class II composite resin restoration has a greater influence on the obtained proximal contact tightness compared to the influence of the consistency of the composite resin.

Download full-text PDF

Source

Publication Analysis

Top Keywords

contact tightness
28
composite resin
24
proximal contact
20
separation ring
20
ivoclar vivadent
12
metal circumferential
12
hand instrument
12
influence composite
8
resin consistency
8
consistency placement
8

Similar Publications

Enabling ultra-flexible inorganic thin-film-based thermoelectric devices by introducing nanoscale titanium layers.

Nat Commun

January 2025

School of Chemistry and Physics, ARC Research Hub in Zero-emission Power Generation for Carbon Neutrality, and Centre for Materials Science, Queensland University of Technology, Brisbane, QLD, Australia.

Here, we design exotic interfaces within a flexible thermoelectric device, incorporating a polyimide substrate, Ti contact layer, Cu electrode, Ti barrier layer, and thermoelectric thin film. The device features 162 pairs of thin-film legs with high room-temperature performance, using p-BiSbTe and n-BiTeSe, with figure-of-merit values of 1.39 and 1.

View Article and Find Full Text PDF

Aim: The aim of the study was to compare and evaluate proximal contact tightness and contours using two newer contact-forming systems in Class II composite restorations.

Materials And Methods: After institutional ethical approval and Clinical Trials Registry-India registration, patients were chosen according to the inclusion-exclusion criteria with informed consent. A total of 60 patients were randomly assigned to two groups.

View Article and Find Full Text PDF

Stroke-related numbness and weakness (SRNW) are resultant disabilities following a stroke episode and may present with muscle weakness, numbness, tightness, spasticity, and pain in up to 85% of patients. Huangqi Guizhi Wuwu Decoction (HGWD) has been widely investigated to manage the sensorimotor deficiencies at the herb and formula level. However, detailed molecular mechanisms of its constituents are presently lacking.

View Article and Find Full Text PDF

Modelling of Fluid Permeability at the Interface of the Metal-to-Metal Sealing Surface.

Materials (Basel)

October 2024

Faculty of Mechanical Engineering and Mechatronics, West Pomeranian University of Technology in Szczecin, 19 Piastow Ave., 70-310 Szczecin, Poland.

This paper presents a method for modelling the permeability of fluid at the interface formed between flat parallel plates and the sharp-edged ridges of a metal gasket. This work was divided into three stages. In the first stage, numerical calculations simulating the deformation (compression of the gasket) were performed.

View Article and Find Full Text PDF
Article Synopsis
  • The study examines the effectiveness of three different matrix systems—Tofflemire, Garrison, and Bioclear—used for Class II composite restorations in premolars and molars, focusing on their ability to create tight proximal contacts and proper contours.
  • Using FDI criteria, the researchers conducted evaluations immediately after restoration placement, employing methods such as flossing and radiographic examination to assess the contact quality and marginal gaps.
  • Statistical analysis indicated significant differences among the matrix systems in terms of the quality of proximal contact and contour, with results processed using SPSS and significance level set at p < 0.05.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!