A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Conformational change of poly(ethylene glycol) near the critical point of isobutyric acid + water. | LitMetric

Conformational change of poly(ethylene glycol) near the critical point of isobutyric acid + water.

J Phys Chem B

Department of Chemical and Biomolecular Engineering, The University of Maryland College Park, College Park, Maryland 20742, USA.

Published: November 2006

In solutions of isobutyric acid + water, poly(ethylene glycol) (PEG) can assume a helical conformation. [Alessi, M. L.; Norman, A. I.; Knowlton, S. E.; Ho, D. L.; Greer, S. C. Macromolecules 2005, 35, 9333-9340.] Here we report new measurements of the kinematic viscosity, nu, as a function of temperature for a solution of isobutyric acid + water at the critical composition, to which PEG (number average molecular weight = 1.01 x10(3) g/mol) was added at a concentration of 6.01 mg/mL. The data show that nu decreases near the critical point, with a maximum in nu at about 0.05 degrees C above the critical temperature, Tc. We interpret this change in nu in terms of a change in conformation of the polymer from helix to coil. This interpretation is supported by polarimetry measurements on the same mixture doped with (S)-(+)-1,2-propanediol, which indicates the loss of helicity near Tc and also a second helix-to-coil transition at about 60 degrees C.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jp056154oDOI Listing

Publication Analysis

Top Keywords

isobutyric acid
12
acid water
12
polyethylene glycol
8
critical point
8
conformational change
4
change polyethylene
4
critical
4
glycol critical
4
point isobutyric
4
water solutions
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!