Temperature is a vital sign which can be measured using various types of clinical thermometers. Pulmonary artery temperature is considered the 'gold standard', but this measurement is not usually clinically practical. There is currently no consensus for optimal alternative site or equipment. This research compares 178 simultaneous measurements from 5 clinical areas, using two types of thermometers: tympanic and no-touch temporal. No-touch thermometers were all set to oral equivalent. Tympanic thermometers were adjusted to either oral (n=105) or core (n=73) equivalent. Maximum acceptable difference was identified as 1oC. Two data sets (oral/core; oral/oral) were analysed using Bland-Altman method on Excel programmes, comparing all thermometers and separating oral and core-equivalent tympanics. The two thermometers were found not to be equivalent. As a simple comparison between two thermometers, this research cannot identify which thermometer is more accurate.

Download full-text PDF

Source
http://dx.doi.org/10.12968/bjon.2006.15.18.22028DOI Listing

Publication Analysis

Top Keywords

thermometers
7
comparing no-touch
4
no-touch tympanic
4
tympanic thermometer
4
thermometer temperature
4
temperature recordings
4
recordings temperature
4
temperature vital
4
vital sign
4
sign measured
4

Similar Publications

Comparison of Temporal Artery and Rectal Temperature Measurement During Cooling and Rewarming in Neonates Treated for Hypoxic Ischemic Encephalopathy.

Adv Neonatal Care

January 2025

Author Affiliations: Neonatal Intensive Care Unit, Seattle Children's Hospital, Seattle, WA (Mrs LaBella, Ms Kelly, Mrs Carlin, and Dr Walsh); and Seattle Children's Research Institute, Seattle, WA (Mrs Carlin and Dr Walsh).

Background: Finding an accurate and simple method of thermometry in the neonatal intensive care unit is important. The temporal artery thermometer (TAT) has been recommended for all ages by the manufacturer; however, there is insufficient evidence for the use of TAT in infants, especially to detect hypothermia.

Purpose: To assess the accuracy of the TAT in hypothermic neonates in comparison to a rectal thermometer.

View Article and Find Full Text PDF

Heatstroke, a global concern exacerbated by climate change, poses significant health risks, potentially leading to multiorgan damage and fatalities. Core body temperature (CBT) is a critical and precise indicator of heatstroke, and its continuous monitoring could serve as a pivotal tool for early detection. Traditional CBT measurements, often invasive (e.

View Article and Find Full Text PDF

Readiness to deliver quality curative care for under-five children at health posts in Ethiopia.

BMC Health Serv Res

January 2025

Department of Health Policy and Management, Faculty of Public Health, Jimma University, Jimma, Ethiopia.

Background: The institutionalization of village health services with salaried community health workers has been established in Ethiopia for over a decade. However, there are serious concerns about the capacity of health posts to provide quality curative care for children under-five.Understanding the readiness of health posts is crucial for improving the care given to sick children.

View Article and Find Full Text PDF

Introduction: Therapeutic advances have allowed more adults aged ≥60 years with acute myeloid leukemia (AML) to receive life-prolonging treatments, with improvement in overall survival. In contrast to other cancers, the onset of AML is often sudden, high-risk treatment decisions must be made quickly, and survival is often compromised due to aging-related conditions (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!