Study Design: Retrospective comparative study of the postoperative subsidence of two interbody devices following posterior or transforaminal lumbar interbody fusion (PLIF/TLIF) for degenerative spondylolisthesis of the lumbar spine.

Objective: To assess certain radiograph characteristics of PLIF/TLIF using two interbody fusion devices at L4-L5.

Summary Of Background Data: PLIF can achieve spinal stabilization with vertebral body support and direct neural decompression. Although various interbody devices have been used in PLIF procedures, no radiographic studies have compared the load-bearing capabilities of open box and fenestrated tube interbody cages.

Methods: Seventy-five patients who underwent one-level PLIF in the L4-L5 [corrected] segment for degenerative spondylolisthesis were retrospectively reviewed with a minimum 2-year follow-up. Fenestrated tube (Group FT: n = 30 [corrected]) or open box (Group OB: n = 45 [corrected]) cages were used for the PLIF procedure. The following radiographic parameters were evaluated to compare the load-bearing capabilities: disc space height (DH); percent increase and decrease of disc height (% IDH and % DDH, respectively); and percent coverage of the cage on the endplate (% CC).

Results: There were no significant differences in the baseline data, including age, segmental instability and osteoporotic status, between the two groups. Anterior %IDH and % CC were significantly higher in Group OB than in Group FT (% IDH: 69.4% vs. 57.3%; % OC: 24.5% vs. 12.9%), and anterior and posterior % DDH were significantly higher in Group FT than in Group OB (anterior: -2.9% vs. -.1%; posterior: -6.6% vs. -.3%). Although the restored DH gradually reduced over time in both groups, significant reduction to the preoperative level only occurred in Group FT.

Conclusions: The load-bearing capabilities of the open box cage are superior to those of the fenestrated tube cage. Since there were no significant differences between the baseline status of the two groups, the larger cross-sectional area and stable framework design of the open box cage appears to bring about a greater load-bearing capability. Therefore, the open box cage seems to be biomechanically more advantageous as an interbody device for PLIF than the fenestrated tube cage.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.brs.0000244593.86975.27DOI Listing

Publication Analysis

Top Keywords

open box
24
fenestrated tube
20
interbody devices
12
interbody fusion
12
load-bearing capabilities
12
box cage
12
interbody
9
comparative study
8
disc height
8
transforaminal lumbar
8

Similar Publications

Objective: To examine the prevalence rate of social anxiety disorder (SAD) among university students in Jordan after the COVID-19 pandemic and its associated predictors.

Design: A cross-sectional online survey study that was conducted in Jordan between January and December 2023.

Setting: Universities in Jordan.

View Article and Find Full Text PDF

This study aimed to investigate the effects of MCC950 in a rat model of sepsis-associated encephalopathy (SAE). Adult male rats were randomly assigned to 12 groups according to the surgery or treatment received and evaluation times. The SAE model was established using the cecal ligation and puncture (CLP) method.

View Article and Find Full Text PDF

Quantum Analog of Landau-Lifshitz-Gilbert Dynamics.

Phys Rev Lett

December 2024

Uppsala University, Department of Physics and Astronomy, Box 516, SE-751 20 Uppsala, Sweden.

The Landau-Lifshitz-Gilbert (LLG) and Landau-Lifshitz (LL) equations play an essential role for describing the dynamics of magnetization in solids. While a quantum analog of the LL dynamics has been proposed in [Phys. Rev.

View Article and Find Full Text PDF

Cell fate decisions during cortical development sculpt the identity of long-range connections that subserve complex behaviors. These decisions are largely dictated by mutually exclusive transcription factors, including CTIP2/Bcl11b for subcerebral projection neurons and BRN1/Pou3f3 for intra-telencephalic projection neurons. We have recently reported that the balance of cortical CTIP2-expressing neurons is altered in a mouse model of DDX3X syndrome, a female-biased neurodevelopmental disorder associated with intellectual disability, autism spectrum disorder, and significant motor challenges.

View Article and Find Full Text PDF

Systematic Study of Hard-Wall Confinement-Induced Effects on Atomic Electronic Structure.

J Phys Chem A

January 2025

Department of Chemistry, Faculty of Science, University of Helsinki, P.O. Box 55, A.I. Virtanens Plats 1, University of Helsinki FI-00014, Finland.

We point out that although a litany of studies have been published on atoms in hard-wall confinement, they have either not been systematic, having only looked at select atoms and/or select electron configurations, or they have not used robust numerical methods. To remedy the situation, we perform in this work a methodical study of atoms in hard-wall confinement with the HelFEM program, which employs the finite element method that trivially implements the hard-wall potential, guarantees variational results, and allows for easily finding the numerically exact solution. Our fully numerical calculations are based on nonrelativistic density functional theory and spherically averaged densities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!