Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN, Lyell's syndrome) are now considered to be distinct clinical entities within a spectrum of adverse cutaneous drug reactions of increasing severity based on their surface of skin detachment. Within this spectrum, SJS which can be considered as a minor form of TEN is characterized by less than 10% body surface area of skin detachment, and an average reported mortality of 1-5%, whereas TEN is characterized by more than 30% skin detachment, and an average reported mortality 25-35%. Both SJS and TEN are characterized morphologically by the rapid onset of keratinocyte cell death by apoptosis, a process that results in the separation of the epidermis from the dermis. Recent evidence is supportive of a role for inflammatory cytokines and the death receptor Fas and its ligand FasL in the pathogenesis of keratinocyte apoptosis during TEN. This Fas-mediated keratinocyte apoptosis that is the last step culminating in epidermal detachment in TEN can be inhibited in vitro by antagonistic monoclonal antibodies to Fas, and by intravenous immunoglobulins (IVIG) which have been shown to contain natural anti-Fas antibodies. Consequently, over the last few years, numerous case reports and 9 non-controlled clinical studies containing 10 or more patients have analyzed the therapeutic effect of IVIG in TEN. Taken together, although each study has its potential biases, 7 of 9 such studies point towards a benefit of IVIG used at doses greater than 2 g/kg on the mortality associated with TEN. These studies should serve as the basis for designing an appropriate prospective trial or for conducting a metaanalysis in the near future, in order to determine the therapeutic efficacy of IVIG in TEN.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2332/allergolint.55.9 | DOI Listing |
Nano Lett
January 2025
School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212003, PR China.
Wearable sweat sensors offering real-time monitoring of biomarker levels suffer from stability and accuracy issues, primarily due to low biomarker concentrations, fluctuating sweat pH, and material detachment from sensor deformation. Here, we developed a wearable sensing system integrated with two advanced electrodes and a flexible microchannel for long-term reliable monitoring of sweat pH and uric acid (UA). By printing the ink doped with nanomaterials (CoO@CuCoO and polyaniline), we achieved highly stable electrodes for the direct analysis of perspiration, without additional surface modification.
View Article and Find Full Text PDFLangmuir
January 2025
Henan Province Engineering Technology Research Center of MEMS Manufacturing and Applications, School of Mechanics and Safety Engineering, Zhengzhou University, Zhengzhou 450001, China.
The rapid development of wearable technology, flexible electronics, and human-machine interaction has brought about revolutionary changes to the fields of motion analysis and physiological monitoring. Sensors for detecting human motion and physiological signals have become a hot topic of current research. Inspired by the muscle fiber structure, this paper proposed a highly stable strain sensor that was composed of stretchable Spandex fibers (SPF), multiwalled carbon nanotubes (MWCNTs), and silicone rubber (Ecoflex).
View Article and Find Full Text PDFVet Ophthalmol
January 2025
Department for Companion Animals and Horses, Ophthalmology Service, University of Veterinary Medicine, Vienna, Austria.
Purpose: To describe a surgical method for correcting lower lid entropion, lateral canthal entropion, and macroblepharon.
Methods: Lid margins were incised at a 45° angle, and lateral lid margins and a rhomboid shaped piece of skin were resected based on the degree of macroblepharon. Subcutaneous tissue was sutured with absorbable sutures and anchored to the orbital ligament with a non-absorbable suture to maintain lateral canthal position.
Zhongguo Zhong Yao Za Zhi
December 2024
College of Pharmaceutical Sciences, Guizhou University of Traditional Chinese Medicine Guiyang 550025, China National Engineering Technology Research Center for Miao Medicine Guiyang 550025, China Guizhou Engineering Technology Research Center for Processing and Preparation of Traditional Chinese Medicine and Ethnic Medicine Guiyang 550025, China.
The conventional acupoint therapy for rheumatoid arthritis often uses traditional Chinese medicine preparations in the dosage forms of powder, ointment, and paste. However, these dosage forms have obvious drawbacks, such as low transdermal absorption, strong skin irritation, and easy detachment. Creating a traditional Chinese medicine acupoint therapy characterized by high penetration, low toxicity, low irritation, and convenient administration is of great significance.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Aier Eye Hospital, Tianjin University, Fukang Road, Tianjin, 300110, China.
Sjögren's syndrome-related dry eye (SSDE) is a severe dry eye subtype characterized by significant immune cell attacks on the lacrimal gland. However, delivering immunosuppressive drugs to the lacrimal glands for SSDE therapy safely and sustainably poses significant challenges in clinical practice. Herein, a ROS-responsive microneedle patch with detachable functionality (CE-MN) is developed to enable straightforward and minimally invasive administration to the lacrimal gland area by penetrating the periocular skin.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!