A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and usefulness of a novel eMotion electric mesh nebulizer in children with asthma. | LitMetric

Background: A new electronic mesh nebulizer, eMotion is known to have higher performance compared to conventional nebulizers. However, there are some concerns about whether too much delivered dose might cause side effects with higher frequency.

Methods: To evaluate the safety and usefulness of the nebulizer, we measured changes in heart rates and lung functions of 73 asthmatic children when they inhaled 1 microg/kg of procaterol with eMotion or a conventional nebulizer, Junior BOY.

Results: In 34 children with mild asthma exacerbation, physical findings, lung function and transcutaneous oxygen saturation levels were improved after inhalation using both nebulizers. No adverse effects including significant increase of heart rate were found. Improvements in the rates of the parameters were comparable. When response to beta2-agonist inhalation was checked in 39 children in stable condition, similar degrees of improvement in lung function were observed, and heart rates did not change after inhalation with either nebulizers.

Conclusions: Safety and efficacy was comparable between eMotion and a conventional nebulizer when it was used to administer beta2-agonists in asthmatic children. However, from the fact that eMotion needs only 3-4 minutes to inhale 2 mL solution, eMotion could be more useful for most children who usually do not prefer longer inhalation time with conventional compressor nebulizers.

Download full-text PDF

Source
http://dx.doi.org/10.2332/allergolint.55.167DOI Listing

Publication Analysis

Top Keywords

mesh nebulizer
8
heart rates
8
asthmatic children
8
emotion conventional
8
conventional nebulizer
8
lung function
8
emotion
6
children
6
nebulizer
5
safety novel
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!