Renal interventions after abdominal aortic aneurysm repair using an aortic endograft with suprarenal fixation.

Am J Surg

Section of Vascular Surgery, Richard L. Roudebush Veterans Affairs Medical Center and Division of Vascular Surgery, Department of Surgery, Indiana University School of Medicine, Indianapolis, IN, USA.

Published: November 2006

Background: Our aim was to determine whether suprarenal fixation in endografts compromises renal artery (RA) flow and whether subsequent RA intervention is precluded by the stent struts.

Methods: Prospectively acquired data from 104 patients with endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm using the Zenith endograft (Cook, Inc., Bloomington, IN) were analyzed. The Zenith device uses a 26-mm, uncovered, barbed Z stent for suprarenal function.

Results: No RA stenosis, occlusion, or infarction resulted from the suprarenal stent. In 3 of 104 (2.9%) patients, RA compromise (2 stenoses, 1 occlusion) was caused by impingement of graft material on the lowermost RA. The 2 RA stenoses were stented successfully at 1 and 7 months post-EVAR. Six of 104 (5.8%) patients developed late stenoses unrelated to the endograft: all were stented successfully from 19 to 36 months after EVAR. One patient with severe RA stenosis had balloon angioplasty pre-EVAR and then was stented electively 6 weeks post-EVAR.

Conclusions: Our data show that the suprarenal fixation of the Zenith aortic endograft does not cause RA stenosis, occlusion, or infarction, nor does it preclude post-EVAR renal artery intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjsurg.2006.08.020DOI Listing

Publication Analysis

Top Keywords

suprarenal fixation
12
abdominal aortic
8
aortic aneurysm
8
aneurysm repair
8
aortic endograft
8
renal artery
8
stenosis occlusion
8
occlusion infarction
8
stented months
8
suprarenal
5

Similar Publications

Background: We analyzed the long-term influence of fixation systems on proximal aortic neck (PAN) evolution by comparing 2 late-generation endoprostheses, Endurant (Medtronic Vascular, Minneapolis, Minn) with suprarenal fixation (SRF) and Excluder (W.L Gore & Associates, Flagstaff, Ariz) with infrarenal fixation (IRF).

Methods: Our retrospective observational study included consecutive patients undergoing endovascular aneurysm repair (EVAR) for aorto-iliac aneurysms (2011-2020).

View Article and Find Full Text PDF

Objective: The main objective of this paper is to evaluate the outcomes regarding endoleaks, reinterventions, and death related to aneurysm complications in patients submitted to endovascular repair (EVAR) for abdominal aortoiliac aneurysm (AAA) using Endurant II (Medtronic) and Zenith Flex (Cook) endografts.

Methods: This was a prospective, consecutive cohort study of patients with AAA who underwent EVAR with the use of Endurant II stent graft and Zenith Flex endograft.

Results: A total of 156 patients submitted to EVAR were evaluated.

View Article and Find Full Text PDF

Explantation of an ALTO abdominal stent graft.

J Vasc Surg Cases Innov Tech

April 2024

Division of Vascular and Endovascular Surgery, Medical College of Wisconsin, Milwaukee, WI.

Explantation of traditional infrarenal aortic endografts has been previously described, and explanation of aortic endografts with standard suprarenal fixation at our center has been well defined. However, to the best of our knowledge, no cases have been reported on explantation of endografts with polymer rings present to facilitate the proximal seal. By obtaining full thoracoabdominal exposure with supraceliac clamping and opening the entire aorta along the graft, we were able to successfully explant the ALTO stent graft with polymer rings.

View Article and Find Full Text PDF

[Secondary ruptures of an abdominal aortic aneurysm treated with a physician-modified fenestrated endograft, endoanchors and finally with open repair].

Orv Hetil

September 2023

1 Semmelweis Egyetem, Általános Orvostudományi Kar, Városmajori Szív- és Érgyógyászati Klinika, Intervenciós Radiológiai Tanszék Budapest, Határőr út 18., 1122 Magyarország.

Secondary rupture is a late complication of endovascular aneurysm repair (EVAR). Open surgery is a technically feasible treatment option in most cases, however, late conversion carries a significant risk of morbidity and mortality, as it usually requires at least partial explantation of the in situ device, which is of major concern especially if suprarenal fixation is present. Endovascular treatment of these cases is usually challenging, especially since the custom-made devices that are often needed are not readily available but having a production time of several weeks.

View Article and Find Full Text PDF

Objective: Suprarenal bare metal stent separation is a rare complication after endovascular aneurysm repair. In this report, two new cases of this type of device failure are presented and the literature is reviewed to identify similar cases and evaluate associated clinical characteristics.

Methods: A literature search was conducted in March 2022 using PubMed, Embase, and The Cochrane Library, with MeSH terms including aortic aneurysm, stents, and device failure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?