Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We prospectively enrolled 20 consecutive patients (11 men and 9 women; mean age 63 +/- 9.5 years) post-AICD implant in a transtelephonic electrocardiographic transmission (TET) program. The monitor was chosen for its retrograde (30 seconds) and antegrade memory capabilities (45 seconds). The patients were discharged from the hospital after receiving instructions to utilize the system for any cardiac symptoms. The monitor was worn 1-3 months (mean 2.5 +/- 0.7 months). During the follow-up period there were 54 TETs received. Nine were for documented AICD discharges, 19 were for symptoms associated with arrhythmias (11 of these 19 reported AICD discharges that were not documented), and 26 for symptoms not associated with arrhythmias. Eight of the 9 AICD discharges documented were appropriate for ventricular tachycardia (mean 185 +/- 40 beats/min). The arrhythmias associated with symptoms were: atrial fibrillation (12); nonsustained ventricular tachycardia (3); ventricular couplets (2); ventricular premature beats (10); and atrial premature contractions (2). Several TETs documented multiple arrhythmias. The most common symptoms not associated with arrhythmias were shortness of breath, dizziness, chest pain, and nervousness. Office interrogation of the AICDs revealed 12 of the 20 patients (60%) had received AICD discharges, with 5 of these 12 patients unaware of this occurring. We found the TET monitoring system a useful tool in the management of the AICD patient the first several months postoperatively. We were able to assess device function and avoid unnecessary office visits and/or hospitalizations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.1991.tb05112.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!