A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-term community hospital experience with the internal defibrillator. | LitMetric

Seventy-seven patients with drug refractory ventricular tachycardia (57) and ventricular fibrillation (20) received the implantable defibrillator. There were 55 men and 22 women with a mean age of 63 +/- 10 years. The anatomical diagnoses were coronary artery disease in 61 patients, cardiomyopathy in 15 patients, and aortic stenosis in one patient. The mean ejection fraction was 32 +/- 12%. Concurrent surgery at defibrillator implantation was coronary bypass in eight patients and aortic valve replacement in one patient. There were no intraoperative mortalities. The mean ventricular fibrillation termination threshold was 13 +/- 6 joules. During a follow-up period of 16 +/- 10 months (range 2-40 months) four patients died: electrical mechanical dissociation (two patients), respiratory failure, and sepsis. Thirty-eight patients (51%) continued receiving antiarrhythmic drug therapy, with quinidine sulfate and procainamide being the most frequently utilized agents. Fifty-four patients (72%) have received a mean of 9 +/- 10 shocks (range 1-44). Implantable defibrillators are often needed in patients seen in large community hospitals. This technology can be administered successfully in this setting with complications and results comparable to those reported from university hospitals. Implantable defibrillators are effective in preventing arrhythmic death and can be used with low risk to the patients.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.1991.tb05104.xDOI Listing

Publication Analysis

Top Keywords

patients
10
ventricular fibrillation
8
patients aortic
8
implantable defibrillators
8
+/-
5
long-term community
4
community hospital
4
hospital experience
4
experience internal
4
internal defibrillator
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!