This cadaveric study sought to evaluate the feasibility of applying a locking proximal humerus plate with a novel minimally invasive technique. A unique pre-contoured locking plate was placed on cadaveric proximal humeri through a described minimally invasive approach. Proximity of the plate and screws to the axillary nerve and their respective surgical tracks were quantified. Safe screw hole placement with respect to the axillary nerve was determined. Risk of entrapment of the nerve beneath the plate was evaluated. Three of the holes near the middle of the locking plate consistently intersected the course of the axillary nerve and were unsafe for percutaneous placement of the screws. The axillary nerve could be palpated during the course of surgery and easily protected from injury. No entrapment of the axillary nerve occurred using this minimally invasive technique. The screw-in locking guide cannot be used with this technique as it caused tenting of the axillary nerve. Placement of a locking proximal humerus plate via a minimally invasive lateral trans-deltoid approach is safe if the locking screws are limited to superior and inferior holes. This can be done safely without entrapment of the axillary beneath the plate. Plate fixation of proximal humerus fractures may now be more desirable with the use of this approach.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2006.08.025DOI Listing

Publication Analysis

Top Keywords

axillary nerve
24
minimally invasive
16
locking plate
12
proximal humerus
12
plate
9
locking proximal
8
humerus plate
8
invasive technique
8
screws axillary
8
beneath plate
8

Similar Publications

Rationale: Patients with atrial fibrillation and a large goiter have high perioperative risks and often cannot tolerate general anesthesia, making it necessary for us to explore new safe and effective anesthesia methods.

Patient Concerns: The patient presented with atrial fibrillation accompanied by rapid ventricular rate, a thrombus attached to the left atrial appendage, and a massive thyroid goiter compressing the airway.

Diagnosis: After the left humerus fracture surgery, the patient's internal fixation loosened and fractured, accompanied by infection, formation of sinus tracts, and suppuration.

View Article and Find Full Text PDF

Background: The incidence of revision shoulder arthroplasty continues to rise, and infection is a common indication for revision surgery. Treatment of periprosthetic joint infection (PJI) in the shoulder remains a controversial topic, with the literature reporting varying methodologies, including the use of debridement and implant retention, single-stage and 2-stage surgeries, antibiotic spacers, and resection arthroplasty. Single-stage revision has been shown to have a low rate of recurrent infection, making it more favorable because it precludes the morbidity of a 2-stage operation.

View Article and Find Full Text PDF

This video aims to describe an endoscopic surgical approach for accessing difficult to reach pathology such as disc herniations after previous surgery. The relatively small size of endoscopic instruments facilitates significant freedom of movement inside the spinal canal. The authors have experience with interlaminar approaches for contralateral pathology such as disc herniations, recurrent disc herniations, spinal stenosis, and facet cysts.

View Article and Find Full Text PDF

Neurofibromatosis type 1 (NF1) is an autosomal dominant genetic multisystem phakomatosis that can affect the skin, bones, and nervous system. NF1 typically presents with skin lesions, including freckles, café-au-lait macules, plexiform neurofibromas, and bony dysplasia, and is usually accompanied by a family history of the disorder. Ocular manifestations vary, but iris Lisch nodules and optic nerve gliomas are the most common features.

View Article and Find Full Text PDF

Carcinoma of unknown primary (CUP) comprises 2-5% of cancer diagnoses worldwide, with a prevalence that has modestly declined with increased availability of advanced diagnostic tools such as next-generation sequencing (NGS). This case presentation illustrates the possibilities and gaps that remain with improving diagnostic capabilities in identifying and effectively treating CUP. This is the case of a rapidly enlarging right axillary mass without a primary tumour site and histological evaluation demonstrating a poorly differentiated neoplasm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!