A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants. | LitMetric

Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants.

Int J Oral Maxillofac Implants

Oral and Maxillofacial Surgery, J Gutenberg University, Hospital Mainz, Germany.

Published: December 2006

Purpose: The aim of this study was to compare insertion torque and resonance frequency analysis of different implant systems in an animal model with loaded implants.

Materials And Methods: Three types of Brånemark implants (machined MkIII, TiUnite MkIII, and MkIV) and 2 types of Straumann implants (sandblasted, large-grit, acid-etched [SLA] and titanium plasma-sprayed [TPS]) were studied. Thirty-two implants of each type (n = 160) were placed in 16 beagle dogs. Maximum insertion torque values were recorded. After a healing period of 8 weeks, the implants were loaded for 3 months; the animals were then sacrificed. At placement, after healing, and at the end of the loading phase, resonance frequency analysis was performed and implant stability quotients (ISQs) were recorded.

Results: Higher insertion torque values were seen for the conical MkIV than for the MkIII. No difference was seen between the Brånemark and Straumann implants on the basis of ISQ value at placement. ISQ and insertion torque values were lower for the cylindric Straumann implants than for the self-tapping implants. For all implant systems a significant decrease in median ISQ was observed, with a median decrease ranging from 3 to 6. ISQ values for self-tapping implants remained stable after loading, whereas the ISQ values for non-self-tapping cylinders decreased. The maximum insertion torque values for failed and successful implants were not significantly different. Significantly higher ISQ values at placement were seen for successful implants (P =.003). Based on this model for ISQ, a threshold of 65.5 was identified, with a sensitivity of 83% and specificity of 61% for prediction of implant loss. ISQ values at the start of loading were not predictive of implant loss in the loading period.

Conclusion: Caution should be used when judging implant systems on the basis of resonance frequency analysis and torque measurement.

Download full-text PDF

Source

Publication Analysis

Top Keywords

insertion torque
24
resonance frequency
16
frequency analysis
16
implant systems
16
torque values
16
isq values
16
straumann implants
12
implants
11
torque resonance
8
systems animal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!