A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Potential of CE for the determination of inorganic and acidic anions in cyanoacrylate adhesives. | LitMetric

AI Article Synopsis

  • A new Capillary Zone Electrophoresis (CZE) method with indirectUV detection was created to analyze several inorganic and acidic anions in cyanoacrylate adhesives.
  • Chromate was used as a probe ion, and cationic surfactant CTAB was added to reverse the electroosmotic flow (EOF) in the background electrolyte (BGE).
  • This method offers faster analysis and better separation compared to traditional methods like ion chromatography, achieving detection limits between 0.7-4.6 microg/mL for the anions tested.

Article Abstract

In this work, a CZE method with indirect UV detection was developed for the simultaneous determination of the inorganic and acidic anions, chloride, sulfate, nitrate, fluoride, formate, phosphate, diethylphosphate, methyl sulfonate, cyanoacetate, and methacrylate present in cyanoacrylate adhesives. Chromate was employed as the probe ion, and the EOF was reversed by incorporating CTAB into BGE. Detection limits of 0.7-4.6 microg/mL were obtained for all the anions studied. The CE method developed is a significant improvement on traditionally used chromatographic methods such as ion chromatography, as it resulted in shorter analysis times with enhanced separation efficiencies. This method was successfully employed for the analysis of inorganic and acidic anions in cyanoacrylate adhesive samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200600247DOI Listing

Publication Analysis

Top Keywords

inorganic acidic
12
acidic anions
12
determination inorganic
8
anions cyanoacrylate
8
cyanoacrylate adhesives
8
potential determination
4
anions
4
adhesives work
4
work cze
4
cze method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!