Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The aim of this study was to evaluate the success rate of combined peritumoral and subdermal injection techniques based on our previous experience on different injection techniques for lymphoscintigraphy.
Patients And Methods: Fifty-nine women with early breast cancer (mean tumor size, 20.5 mm) were prospectively studied. On the morning of the operation, each patient had 2 injections, one peritumoral (PT) medial to the lesion and one subdermal (SD) into the skin over the tumor quadrant. Each injection consisted of 20 MBq (540 mCi) Tc-99m rhenium sulfide colloid. Early dynamic and delayed static images were obtained up to 4 hours after injections. An intraoperative gamma probe was used to explore the axillary sentinel lymph nodes (SLN). All surgical specimens were evaluated histopathologically.
Results: Forty patients had breast-preserving surgery and 19 had modified radical mastectomy. Thirty-eight patients had axillary dissection. All but 4 patients showed axillary lymphatic drainage. Twelve of 59 patients (20%) showed extraaxillary drainage with lymphoscintigraphy. Combined injection technique yielded a 93.2% success rate in detecting axillary SLN. In 2 of 4 patients with no drainage on lymphoscintigraphy, intraoperative gamma probe revealed SLN during the surgery. Twenty patients (33%) had positive axillary lymph nodes. In 14 of them, the SLN was the only positive node. A false-negative rate was found 1.6% (one of 59 patients).
Conclusion: This results suggest that a combination of both PT and SD techniques increases the success rate of visualization SLN and enhances the visualization of extraaxillary nodes for further treatment planning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.rlu.0000242603.06844.81 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!