Atlantoaxial fixation using the polyaxial screw-rod system.

Eur Spine J

Spine Surgery Department, Teaching Hospital Prague Motol, Prague 5, Czech Republic.

Published: April 2007

The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw-rod system. Twenty-eight patients followed-up 12-29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23-89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1-C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1-C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1-C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2229812PMC
http://dx.doi.org/10.1007/s00586-006-0241-6DOI Listing

Publication Analysis

Top Keywords

temporary fixation
12
vertebral artery
12
atlantoaxial fixation
8
fixation polyaxial
8
polyaxial screw-rod
8
screw-rod system
8
patients
8
operative time
8
screws
8
nerve structures
8

Similar Publications

Background: This study aimed to analyze the files of patients treated using PFN-A or INTERTAN intramedullary nails to reveal additional superiorities or disadvantageous factors for selecting the better intramedullary fixation method in patients presenting with intertrochanteric femur fractures.

Methods: In this retrospective study, the files of the patients who were operated on for intertrochanteric femur fractures using intramedullary fixation methods between September 2010 and June 2015 in the Orthopedics and Traumatology Clinic, Çukurova University Faculty of Medicine, were reviewed. The data including age, gender, chronic diseases, causes of fractures, fracture classification based on Arbeitsgemeinschaft für Osteosynthesefragen (AO), the nail type (long or short), the interval between trauma and surgery, duration of anesthesia and surgery, hospitalization duration, amount of blood transfusion, the Tip-Apex Distance (TAD) in postoperative radiographs, functional outcomes according to Harris Hip Score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), postoperative complications, need for revision, and mortality was noted.

View Article and Find Full Text PDF
Article Synopsis
  • Knee pain often involves varus deformity and unicompartmental osteoarthritis, where high tibial valgus osteotomy (HTO) has emerged as an effective treatment option to delay joint replacement.
  • A case report highlighted two patients with bilateral knee arthritis who underwent medial opening-wedge high tibial osteotomy using Dr. Saigal's plate, both achieving good range of motion and minimal complications post-surgery.
  • Comprehensive evaluations, including radiological assessments and specific surgical techniques like the Miniaci Method, were employed to ensure successful outcomes, with both patients showing significant improvement after one year.
View Article and Find Full Text PDF

Background: Distal radius fractures are prevalent in small and toy-breed dogs, presenting significant treatment challenges due to complications such as delayed union or non-union. These complications are often exacerbated by reduced vascular density at the distal diaphyseal-metaphyseal junction of the radius, which is vital for bone healing, particularly in toy and small breed dogs. Circular external fixation (CEF) is known for its effectiveness in managing acute and chronic fractures and providing temporary stabilization in humans.

View Article and Find Full Text PDF

To measure the life quality, clinical-functional outcomes of a patient who had undergone acute reconstruction of radio scapho capitate (RSC), radio lunate (RLL) ligaments, using brachiorradialis tendon in treatment of radiocarpal fracture dislocation. 21-years-old, man with radiocarpal fracture dislocation in his left wrist, after motorcycle accident. Percutaneous screw fixation of the distal radius and acute reconstruction of the RSC and RLL was performed, assisted by arthroscopy.

View Article and Find Full Text PDF

The reported case describes a traumatic anterior knee dislocation of a previous asymptomatic knee after a posterior cruciate-retaining primary knee arthroplasty. The described patient accidentally rolled over her knee six years after the surgical intervention. Anterior traumatic dislocation after knee arthroplasty is an uncommon event often leading to prosthetic's components revision due to its associated ligament injuries.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!