A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preparation and characterization of long alkyl chain methacrylate-based monolithic column for capillary chromatography. | LitMetric

This paper describes the fabrication of long alkyl chain methacrylate monolithic materials for using as stationary phases in capillary liquid chromatography. Following deactivation of the capillary surface with 3-(trimethoxysilyl)propyl methacrylate (gamma-MAPS), monoliths were formed by co-polymerisation of stearyl methacrylate (SMA) with ethylene glycol dimethacrylate (EDMA) in the presence of the initiator AIBN and a mixture of porogens including iso-amyl alcohol and 1,4-butanediol. The monoliths were prepared in 100 microm i.d. capillaries and the composition of the polymerisation mixtures were optimised in terms of the ratio of SMA/EDMA, the porogen composition and ratio of porogen to monomers. As the porogen weight fraction decreased, the microglobules became smaller and as expected, the total porosity decreased. In order to determine the usability of such materials, the column permeability K was measured by pumping water through the columns at different linear flow rates. Good results were obtained when these capillaries were used to separate mixtures of weak acids, neutral and basic compounds.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbbm.2006.08.009DOI Listing

Publication Analysis

Top Keywords

long alkyl
8
alkyl chain
8
preparation characterization
4
characterization long
4
chain methacrylate-based
4
methacrylate-based monolithic
4
monolithic column
4
column capillary
4
capillary chromatography
4
chromatography paper
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!