A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flat ended steel wires, backscattering targets for calibrating over a large dynamic range. | LitMetric

Flat ended steel wires, backscattering targets for calibrating over a large dynamic range.

Ultrasound Med Biol

Department of Biomedical Engineering, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.

Published: October 2006

A series of flat ended stainless steel wires was constructed and experimentally evaluated as point targets giving a calibrated backscattering over a large range (up to 72 dB) for ultrasound frequencies in the range 2 to 10 MHz. Over a range of 36 dB, theory was strictly followed (within +/- 1 dB), giving proportionality with the square of the frequency and the fourth power of the diameter. In this range, the relative scattering strength of targets does not depend on the frequency content of the ultrasound pulse. A deviation of maximal 5 dB at the low side is tentatively ascribed to a failure of simple theory for target diameters smaller than half a wavelength. For large diameters, backscattering is sensitive to orientation of the target: a numerical relation between misalignment and desired accuracy is proposed. A replication test for targets with a diameter of 0.24 mm gave equal scattering strengths within 0.8 dB. It is proposed to apply the targets for calibration of the dynamic range of a scanner and as point targets to establish resolution in three perpendicular directions, axial, lateral and elevational.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2006.05.026DOI Listing

Publication Analysis

Top Keywords

flat ended
8
steel wires
8
dynamic range
8
point targets
8
targets
6
range
6
ended steel
4
wires backscattering
4
backscattering targets
4
targets calibrating
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!