The daily exposure to Ni from food, industrial processes, jewellery and coins makes the determination of Ni in human serum an important way to monitor the health status in non-occupationally exposed subjects. To this end, a method based on sector-field inductively coupled plasma mass spectrometry was developed and validated. The limits of detection (LoD) and quantification (LoQ), sensitivity, linearity range, trueness, repeatability, within-laboratory reproducibility and robustness were the considered issues of the validation process. The uncertainty associated with the measurements was also calculated, according to the Eurachem/Citac Guide. The method LoD and LoQ were 0.03 and 0.09 ng mL(-1), linearity was over two order of magnitude, trueness was -3.57%, and the repeatability and reproducibility showed relative standard deviations equal to 4.56% and 6.52%, respectively. The relative expanded uncertainty was 21.8% at the Ni levels found in the general population. The tentative reference value for serum Ni was 0.466 +/- 0.160 ng mL(-1) with a related interval between 0.226 and 1.026 ng mL(-1).

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.2731DOI Listing

Publication Analysis

Top Keywords

sector-field inductively
8
inductively coupled
8
coupled plasma
8
plasma mass
8
mass spectrometry
8
tentative reference
8
nickel quantification
4
quantification serum
4
serum validated
4
validated sector-field
4

Similar Publications

Article Synopsis
  • ALS is a serious and fatal disease affecting motor neurons, and the FDA recently approved tofersen for treating adults with SOD1 gene mutations.
  • A study measured selenium levels in the cerebrospinal fluid of ALS patients before and after tofersen treatment, using advanced mass spectrometry techniques.
  • Results showed that tofersen significantly increased selenium concentrations, suggesting it may impact the brain's redox status, indicating a need for further research on the drug's effects and disease progression.
View Article and Find Full Text PDF

Rationale: The use of a frequency-scanned digital quadrupole mass filter (QMF) with varying duty cycles shows promise for application as a high-resolution mass analyzer design for inductively coupled plasma mass spectrometry (ICP-MS). High resolution in ICP-MS is important to overcome isobaric polyatomic interferences. Here, we explore the possibility and the characteristics of using a digital quadrupole operating in higher stability regions for ICP-MS.

View Article and Find Full Text PDF

We present a method for the determination of ultra-trace Te species (Te(IV) and Te(VI)) in open ocean waters. The proposed method is based on Mg(OH) coprecipitation, anion exchange resin column separation and inductively coupled plasma sector-field mass spectrometry (ICPSFMS) using a Te-enriched isotope spike. The largest advantage of the method is that the use of the spike allows accurate and precise determination when it combines with either isotope dilution or recovery correction.

View Article and Find Full Text PDF

Rationale: Potassium (K) is a major component of several silicate minerals and seawater, and, therefore, constraining past changes in the potassium cycle is a promising way of tracing large-scale geological processes on Earth. However, [K] measurement using inductively coupled plasma mass spectrometry (ICP-MS) is challenging due to an ArH interference, which may be of a similar magnitude to the K ion beam in samples with <0.1% m/m [K].

View Article and Find Full Text PDF

Determination of ultra-trace level Am in marine sediment and seawater by combining TK200-TK221 tandem-column extraction chromatography and SF ICP-MS.

Talanta

May 2024

International Atomic Energy Agency, Environment Laboratories, 4 Quai Antoine 1er, Principality of Monaco, 98000, Monaco.

Sound strategies for marine chemical monitoring call for measurement systems capable of producing comparable analytical results with demonstrated quality. This work presents the development and validation of a new analytical procedure for the determination of the Am mass fraction in marine sediment and seawater samples at low levels. The procedure includes a tandem-column extraction chromatography for separation of Am and sector field-inductively coupled plasma mass spectrometry (SF ICP-MS) for its determination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!