We compared two different magnetic resonance (MR) sequences [steady-state free precession (SSFP) and gradient echo fast low-angle shot (FLASH)] for the assessment of aortic valve areas in aortic stenosis using transesophageal echocardiography (TEE) as the standard of reference. Thirty-two patients with known aortic stenosis underwent MR (1.5 T) using a cine SSFP sequence and a cine FLASH sequence. Planimetry was performed in cross-sectional images and compared to the results of the TEE. In seven patients the grade of stenosis was additionally assessed by invasive cardiac catheterization (ICC). The mean aortic valve area measured by TEE was 0.97+/-0.19 mm(2), 1.00+/-0.25 mm(2) for SSFP and 1.25+/-0.23 mm(2) based on FLASH images. The mean difference between the valve areas assessed based on SSFP and TEE images was 0.15+/-0.13 cm(2) (FLASH vs TEE: 0.29+/-0.17 cm(2)). Bland-Altman analysis demonstrated that measurements using FLASH images overestimated the aortic valve area compared to TEE. Comparing ICC with MRI and TEE, only a weak to moderate correlation was found (ICC vs TEE: R=0.52, p=0.22; ICC vs SSFP: R=0.20, p=0.65; ICC vs FLASH: R=0.16, p=0.70). Measurements of the aortic valve area based on SSFP images correlate better with TEE compared to FLASH images.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-006-0437-5 | DOI Listing |
Cardiovasc Diabetol
January 2025
Department of Cardiology, the First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan 2nd Road, Guangzhou, 510080, China.
Background: Triglyceride-glucose-BMI (TyG-BMI) index is a surrogate marker of insulin resistance and an important predictor of cardiovascular disease. However, the predictive value of TyG-BMI index in the progression of non-severe aortic stenosis (AS) is still unclear.
Methods: The present retrospective observational study was conducted using patient data from Aortic valve diseases RISk facTOr assessmenT andprognosis modeL construction (ARISTOTLE).
Pediatr Cardiol
January 2025
Pediatric Intensive Care Department, Wolfson Medical Center, Holon, Israel.
Research establishing factors associated with duration of mechanical ventilation after Tetralogy of Fallot repair, is mainly based on population presenting at early infancy. There are fewer reports regarding repair after infancy, during childhood and preadolescence. To compare two groups of late TOF repair based on post-operative invasive mechanical ventilation duration and explore associations with pre-operative clinical markers of severity of right ventricular outflow tract obstruction.
View Article and Find Full Text PDFJ Cardiothorac Vasc Anesth
January 2025
Division of Congenital Cardiac Anesthesiology, University of Alabama at Birmingham School of Medicine, Birmingham, AL; Bruno Pediatric Heart Center, Children's of Alabama, Birmingham, AL. Electronic address:
JACC Cardiovasc Interv
January 2025
Ascension St Vincent Heart Center of Indiana, Indianapolis, Indiana, USA.
Background: The optimal timing for percutaneous coronary intervention (PCI) in patients undergoing transcatheter aortic valve replacement (TAVR) is debatable.
Objectives: The aim of this study was to compare outcomes based on the timing of PCI in stable coronary artery disease patients undergoing TAVR.
Methods: Leveraging the STS/ACC TVT Registry and Medicare Linkage, we analyzed patients with stable coronary artery disease undergoing PCI and TAVR between 2015 and 2023 using the SAPIEN 3 balloon-expandable valve platform.
JACC Cardiovasc Interv
January 2025
Institut Cardiovasculaire Paris-Sud, Hôpital Privé Jacques Cartier, Ramsay-Santé, Massy, France. Electronic address:
Background: The prevalence of coronary artery disease in patients undergoing transcatheter aortic valve replacement (TAVR) is high. Treatment of a coronary events (CE) after TAVR can be technically challenging.
Objectives: The authors sought to assess the incidence and prognostic impact of CE after TAVR.