Ultrasonography of the prostate furnishes images which still cannot be fully interpreted morphologically. In a cadaver study, the ultrasound images of two groups (21 and 19) prostates, obtained in a water bath, were compared with histology slides taken at corresponding levels. In the first part of the study, using a 4 MHz probe, there was a correlation between hyperechoic lesions and stone formations in 9 out of 15 cases. A relation between hypoechoic lesions and the existence of a carcinoma could also be established in 4 out of 12 cases. In the second part of the study, using a 7 MHz probe, there was a correlation between hyperechoic lesions and stone formations in all cases. Hypoechoic lesions correlated with the presence of a carcinoma in 1 out of 8 cases. The technique used appears to be well suited for the comparative study of ultrasound images and histology. Application of the 7 MHz probe is preferable as, because of a better resolution, smaller lesions can be detected. The results of this study are not very encouraging for the use of transrectal ultrasound for the detection of small prostatic carcinomas.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0301-5629(90)90099-xDOI Listing

Publication Analysis

Top Keywords

mhz probe
12
study ultrasound
8
ultrasound images
8
study mhz
8
probe correlation
8
correlation hyperechoic
8
hyperechoic lesions
8
lesions stone
8
stone formations
8
formations cases
8

Similar Publications

Evaluation of TOCSY mixing for sensitivity-enhancement in solid-state NMR and application of 4D experiments for side-chain assignments of the full-length 30 kDa membrane protein GlpG.

J Biomol NMR

January 2025

Research Unit Molecular Biophysics, Leibniz-Forschungsinstitut für Molekulare Pharmakologie, Robert- Rössle-Straße 10, 13125, Berlin, Germany.

Chemical shift assignments of large membrane proteins by solid-state NMR experiments are challenging. Recent advancements in sensitivity-enhanced pulse sequences, have made it feasible to acquire H-detected 4D spectra of these challenging protein samples within reasonable timeframes. However, obtaining unambiguous assignments remains difficult without access to side-chain chemical shifts.

View Article and Find Full Text PDF

Objective: The aim of this work is to demonstrate how the chronicity of low back pain can modify the trophism of the paraspinal muscles, by performing an ultrasound and MRI evaluation of the paraspinal muscles in the lumbar spine and correlating it to the time of onset of low back pain.

Materials And Methods: An ultrasound evaluation was carried out in the lumbar area with a 5-17 MHz linear probe of the paraspinal muscles of the lumbar region, compared with the MRI of the lumbar spine, in patients presented to our attention for chronic low back pain (> 6 months), from January 2021 to January 2023. In each patient, two series of images were analyzed, in the coronal and sagittal planes.

View Article and Find Full Text PDF

Brain temperature mapping based on chemical exchange saturation transfer signal at 2 ppm.

Quant Imaging Med Surg

January 2025

Paul. C. Lauterbur Research Centers for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.

Background: Brain temperature signifies the thermal homeostasis of the tissue, and may serve as a marker for neuroprotective therapy. Currently, it remains challenging to map the human brain temperature with high spatial resolution. The thermal dependence of chemical exchange saturation transfer (CEST) effects of endogenous labile protons may provide a promising mechanism for the absolute brain temperature imaging.

View Article and Find Full Text PDF

Ultrasound-guided peripheral intravenous access in adults: A randomized crossover controlled trial.

Int Emerg Nurs

January 2025

Nursing Department, Chi-Mei Medical Center, Taiwan; Department of Senior Welfare and Services, Southern Taiwan University of Science and Technology, Taiwan. Electronic address:

Background: Peripheral intravenous access is a common invasive clinical procedure, and difficult peripheral intravenous access is a common problem in the care of emergency and critically ill patients. The timeliness of immediate treatment is affected by the difficulty of intravenous access in clinical practice, which endangers patient safety. Repeated injections increase the pressure on nursing staff, consume more nursing hours, and incur higher medical costs.

View Article and Find Full Text PDF

Purpose: Redox homeostasis plays a key role in regulating the overall health and development of organisms. This study aimed to develop a compact and mobile continuous-wave (CW) electron paramagnetic resonance (EPR) imager to facilitate stable, highly sensitive fast three-dimensional (3D) whole-body imaging of nitroxide-infused mice.

Methods: A multiturn loop gap resonator with a diameter of 30 mm and length of 35 mm was designed for whole-body EPR imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!