Purpose: Silicone hydrogel (SiH) lenses offer many physiological advantages for daily wear (DW) in addition to the continuous-wear modality for which they were originally developed. The purpose of this study was to investigate the clinical performance and physiological responses in a group of successful long-term wearers of conventional hydrogel lenses when refitted with DW SiH contact lenses.

Methods: Eighty-seven successful soft lens wearers (8.4+/-4.7 years of prior lens wear) participated in this study. Bulbar and limbal hyperemia were subjectively graded and digitally photographed for subsequent masked objective evaluation. Subjective symptoms were scored using visual analog scales. In addition, refractive error, corneal curvature, and corneal thickness were measured. All subjects were refitted with Focus Night & Day (lotrafilcon A) SiH lenses; however, to reduce the potential for bias, they were informed that they were being randomly assigned to wear either low oxygen permeability (Dk) lenses or high Dk SiH lenses and were "masked" as to their lens assignment. Subjects returned after 1 week, 1 month, and 2 months of DW, at which time all gradings, photographs, and measurements were repeated. End-of-day subjective symptoms were also graded periodically during the study.

Results: Ninety-three percent of subjects were successfully refitted. Both objective and subjective evaluations showed that bulbar and limbal hyperemia decreased significantly in all quadrants during the study (p<0.001), particularly for those subjects with greater baseline hyperemia (p<0.001). Subjects reported a concurrent reduction in end-of-day dryness and improved end-of-day comfort compared with their habitual lenses (p<0.001). No significant changes in refractive error, tarsal papillary response, corneal curvature, or corneal thickness were found during the study.

Conclusions: Hyperemia in contact lens wearers may be attributed to a number of factors, including hypoxia. Refitting existing low Dk lens wearers with SiH lenses on a DW basis can result in a decrease in hyperemia, which may be significant for some subjects and also results in improvements in symptoms of dryness and discomfort.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.opx.0000237547.35542.b8DOI Listing

Publication Analysis

Top Keywords

sih lenses
12
objective subjective
8
silicone hydrogel
8
bulbar limbal
8
limbal hyperemia
8
subjective symptoms
8
subjects refitted
8
lenses
6
subjective responses
4
responses patients
4

Similar Publications

Background: Transepithelial corneal crosslinking (CXL) is a novel surgical approach for the treatment of keratoconus, which is a bilateral asymmetrical ophthalmological disease accompanied by progressive corneal ectasia. Silicon hydrogel (SiH) contact lenses have been extensively used in clinical ophthalmologic medicine, as a postoperative ophthalmological intervention. However, the ideal lens application duration after transepithelial CXL remains uncertain.

View Article and Find Full Text PDF

Corneal hysteresis and intraocular pressure are altered in silicone-hydrogel soft contact lenses wearers.

Int Ophthalmol

September 2022

Departamento de Física Aplicada, Universidad de Zaragoza, C/ Pedro Cerbuna, 12, 50009, Zaragoza, Spain.

Purpose: The aim of this work is to determinate the effects in the physical parameters in terms of intraocular pressure (IOP) and central corneal thickness (CCT) and corneal biomechanics in terms of corneal resistance factor (CRF) and corneal hysteresis (CH) of wearing silicone-hydrogel soft contact lenses (SiH-CLs) in young adult subjects during a short-term follow-up.

Methods: 40 eyes of 20 healthy patients with a mean age of 22.87 ± 4.

View Article and Find Full Text PDF

Effect of material and care system combination on subclinical inflammation of the ocular surface in soft contact lens wear.

Cont Lens Anterior Eye

August 2022

Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom.

Purpose: To investigate the ocular subclinical inflammatory response in two soft contact lens materials when used in combination with two different care systems ('solutions').

Methods: Fifteen established soft contact lens wearers wore each of two lenses: Acuvue® 2 (CH) and Acuvue® Oasys® (SiH) or no lenses in random sequence for one week. Two care systems were used: a peroxide system: Oxysept 1 Step® (P) for the right lens and Opti-Free® Replenish® (MPS) for the left lens.

View Article and Find Full Text PDF

Shape of the anterior surface of the cornea after extended wear of silicone hydrogel soft contact lenses.

Ophthalmic Physiol Opt

July 2021

Division of Ophthalmology and Optometry, Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland.

Purpose: To measure geometrical changes in the anterior surface of the cornea after wearing silicon hydrogel (SiH) soft contact lenses continuously for 1 week.

Methods: Forty-three eyes with 3.0D of myopia and 22 eyes with 3.

View Article and Find Full Text PDF

Silicone-hydrogel (SiH) contact lenses are frequently used as a bandage after anterior segment surgical procedures. Several types of lenses may exhibit clinical performances with different characteristics. This study aims to evaluate the efficacy of two SiH contact lenses following corneal crosslinking (CXL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!