Progress report of the CR-39 neutron personal monitoring service at PSI.

Radiat Prot Dosimetry

Paul Scherrer Institute, CH-5232 Villigen PSI, Switzerland.

Published: September 2008

At the Paul Scherrer Institute a personal neutron dosimetry system based on chemically etched CR-39 detectors and automatic track counting is in routine use since the beginning of 1998. The quality of the CR-39 detectors has always been a crucial aspect to maintain a trustable personal neutron dosimetry system. This paper summarises the 7 y experience in routine use. The effect of detector material defects which could lead to false positive neutron doses is described. The potentiality of improving the background statistics by extending the pre-etch time is investigated and involves as a drawback a quite lower sensitivity to thermal neutrons. Furthermore, the impact of small changes in the production process of the detectors on the response to fast and thermal neutrons is shown. For the personal dosimetry at CERN, a new dosimetry concept was launched by combining a CR-39 neutron dosemeter with a Direct-Ion Storage (DIS) dosemeter for photon and beta radiation. The usage period of the CR-39 dosemeters is prolonged now from 3 months up to 12 months. In this context, the long-term behaviour over 1 y of the background track density and the response to Am-Be are described.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncl114DOI Listing

Publication Analysis

Top Keywords

cr-39 neutron
8
personal neutron
8
neutron dosimetry
8
dosimetry system
8
cr-39 detectors
8
thermal neutrons
8
cr-39
5
neutron
5
progress report
4
report cr-39
4

Similar Publications

Nuclear activation affects all operating, future, or dismantled particle accelerators used in various fields, from medical applications to industrial applications. This work is concerned with the study of the radioactivity induced in various materials (Sc, Cu, Tb, Ta, W, Au) irradiated by hard Bremsstrahlung photons from an electron beam and by secondary neutrons induced by a proton beam. In both cases, the primary beam features an 18 MeV kinetic energy.

View Article and Find Full Text PDF

Photon and Neutron Dose Estimation Using Monte Carlo Simulation in TrueBeam's Room.

J Med Phys

September 2024

Department of Health Sciences, Division of Medical Quantum Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.

Purpose: The distribution of neutron ambient dose equivalent within the TrueBeam 10 MV photon chamber was investigated.

Materials And Methods: The research used particle and heavy ion transport code system (PHITS) code and JENDL-5.0 to simulate the neutron ambient dose equivalent on and around TrueBeam's head.

View Article and Find Full Text PDF

Quantifying the effects of neutron fluence on proton signal retention in CR-39.

Rev Sci Instrum

October 2024

Massachusetts Institute of Technology, Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA.

Article Synopsis
  • The paper examines how higher neutron fluences affect the detection efficiency of protons using CR-39, a common particle detection method, particularly in inertial fusion diagnostics.
  • Experiments revealed that as neutron fluence increases, the recovery of proton signals decreases, with added complications from longer etching times.
  • Notably, at 3 hours of etching, a 17% signal loss was observed with high neutron tracks, escalating to 67% at 6 hours, though improved signal isolation techniques can mitigate some of this loss.
View Article and Find Full Text PDF

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately.

View Article and Find Full Text PDF

Electrolysis of DO may be used as a portable neutron source with numerous applications without the complexity of huge reactor operations. Herein, we report reproducible fast neutron generation by electrolysis of DO using palladium cathode and platinum anode, which was detected with diamond detector, gas filled He detectors after thermalisation with high density polythene, as well as novel epoxy resin and CR-39 detectors. Notably, a highly reproducible neutron generation at electrochemical surfaces of palladium electrode was observed and signature transmutation via Pd (d, n) Ag was corroborated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!