Purpose: To assess the clinical relevance of dark-lumen MR colonography (MRC) for the detection of colorectal lesions using conventional colonoscopy (CC) and histopathologic examinations as reference standard.

Materials And Methods: A total of 72 patients underwent MRC and CC. MRC was performed using a contrast-enhanced high spatial resolution T1 weighted 3D volumetric interpolated breathhold examination (VIBE)-sequence. All removed colorectal lesions were evaluated by an experienced pathologist.

Results: CC confirmed 65 polyps less than 5 mm in diameter. Non of those lesions could be detected using MRC. Just two (4%) of the 49 removed lesions smaller than 5 mm showed signs of dysplasia. Additionally, CC confirmed 25 polyps between 6-15 mm in diameter (MRC 22). All those 25 lesions were removed in CC. Only four (16%) of those polyps showed signs of dysplasia and malignancy (11, 13, 13 and 15 mm).

Conclusion: Dark-lumen MRC failed to detect all polyps smaller than 5 mm in diameter which are generally not clinically relevant at the moment of their detection and thus can be kept under surveillance. However, MRC as a non-invasive imaging modality is a promising alternative to CC in the detection of clinically relevant polyps larger than 5 mm in diameter.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.20734DOI Listing

Publication Analysis

Top Keywords

dark-lumen colonography
8
clinical relevance
8
polyps smaller
8
smaller diameter
8
moment detection
8
colorectal lesions
8
confirmed polyps
8
signs dysplasia
8
clinically relevant
8
mrc
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!